Engineering topics
Zhang, Xinyuan
Publications and source records attributed to Zhang, Xinyuan.
High-throughput manufacturing of epitaxial membranes from a single wafer by 2D materials-based layer transfer process
Layer transfer techniques have been extensively explored for semiconductor device fabrication as a path to reduce costs and to form heterogeneously integrated devices. These techniques entail isolating epitaxial layers from an expensive donor wafer to form freestanding membranes. However, current layer transfer processes are still low-throughput and too expensive to be commercially suitable. Here we report a high-throughput layer transfer technique that can produce multiple compound semiconductor membranes from a single wafer. We directly grow two-dimensional (2D) materials on III–N and III–V substrates using epitaxy tools, which enables a scheme comprised of multiple alternating layers of 2D materials and epilayers that can be formed by a single growth run. Each epilayer in the multistack structure is then harvested by layer-by-layer mechanical exfoliation, producing multiple freestanding membranes from a single wafer without involving time-consuming processes such as sacrificial layer etching or wafer polishing. Moreover, atomic-precision exfoliation at the 2D interface allows for the recycling of the wafers for subsequent membrane production, with the potential for greatly reducing the manufacturing cost.
Probing the Potential Energy Profile of the I + (H 2 O) 3 → HI + (H 2 O) 2 OH Forward and Reverse Reactions: High Level CCSD(T) Studies with Spin-Orbit Coupling Included
Three different pathways for the atomic iodine plus water trimer reaction I + (H 2 O) 3 → HI + (H 2 O) 2 OH were preliminarily examined by the DFT-MPW1K method. Related to previous predictions for the F/Cl/Br + (H 2 O) 3 reactions, three pathways for the I + (H 2 O) 3 reaction are linked in terms of geometry and energetics. To legitimize the results, the “gold standard” CCSD(T) method was employed to investigate the lowest-lying pathway with the correlation-consistent polarized valence basis set up to cc-pVQZ(-PP). According to the CCSD(T)/cc-pVQZ(-PP)//CCSD(T)/cc-pVTZ(-PP) results, the I + (H 2 O) 3 → HI + (H 2 O) 2 OH reaction is predicted to be endothermic by 47.0 kcal mol -1 . The submerged transition state is predicted to lie 43.7 kcal mol -1 above the separated reactants. The I···(H 2 O) 3 entrance complex lies below the separated reactants by 4.1 kcal mol -1 , and spin-orbit coupling has a significant impact on this dissociation energy. The HI···(H 2 O) 2 OH exit complex is bound by 4.3 kcal mol -1 in relation to the separated products. Compared with simpler I + (H 2 O) 2 and I + H 2 O reactions, the I + (H 2 O) 3 reaction is energetically between them in general. It is speculated that the reaction between the iodine atom and the larger water clusters may be energetically analogous to the I + (H 2 O) 3 reaction. The iodine reaction I + (H 2 O) 3 is connected with the analogous valence isoelectronic bromine/chlorine reactions Br/Cl + (H 2 O) 3 but much different from the F + (H 2 O) 3 reaction. Significant difference with other halogen systems, especially for barrier heights, are seen for the iodine systems.
Intrinsically stretchable electrode array enabled in vivo electrophysiological mapping of atrial fibrillation at cellular resolution
Electrophysiological mapping of chronic atrial fibrillation (AF) at high throughput and high resolution is critical for understanding its underlying mechanism and guiding definitive treatment such as cardiac ablation, but current electrophysiological tools are limited by either low spatial resolution or electromechanical uncoupling of the beating heart. To overcome this limitation, here we introduce a scalable method for fabricating a tissue-like, high-density, fully elastic electrode (elastrode) array capable of achieving real-time, stable, cellular level-resolution electrophysiological mapping in vivo. Testing with acute rabbit and porcine models, the device is proven to have robust and intimate tissue coupling while maintaining its chemical, mechanical, and electrical properties during the cardiac cycle. The elastrode array records epicardial atrial signals with comparable efficacy to currently available endocardial-mapping techniques but with 2 times higher atrial-to-ventricular signal ratio and >100 times higher spatial resolution and can reliably identify electrical local heterogeneity within an area of simultaneously identified rotor-like electrical patterns in a porcine model of chronic AF.