Search NASA⌕ Search

Engineering topics

Zhang, Zhuquan (ORCID:0000000195699800)

Publications and source records attributed to Zhang, Zhuquan (ORCID:0000000195699800).

Terahertz stimulated parametric downconversion of a magnon mode in an antiferromagnet

Parametric amplification, where one signal is enhanced by the action of another, offers both practical utility for boosting weak signals and fundamental insights into the nonlinear coupling between degrees of freedom. In condensed matter systems, interactions between collective modes offer avenues for nonlinear coherent manipulation of coupled excitations and quantum phases. Antiferromagnets, with inherently coupled magnon modes, provide a promising platform for nonlinear control of spin waves and magnetization. However, nonlinear magnon-magnon interactions have been only partially elaborated, leaving key gaps in the prospects for potential ultrahigh-bandwidth magnonic signal processing. Here, we excite two distinct coherent magnon modes in an antiferromagnet and find that the magnon mode with a lower frequency undergoes amplification when the higher-frequency mode is driven. We unveil the nonlinear excitation pathways of this stimulated parametric downconversion process by using polarization-selective two-dimensional terahertz spectroscopy. Our work provides fundamental insights into nonlinear magnonics in antiferromagnets, laying the groundwork for forthcoming spintronic and magnonic devices.

Science & Technology - Other Topics↗

Optical-pump–terahertz-probe spectroscopy in high magnetic fields with kHz single-shot detection

We demonstrate optical pump–THz probe (OPTP) spectroscopy with a variable external magnetic field (0–9 T), in which the time-dependent THz signal is measured by echelon-based single-shot detection at a repetition rate of 1 kHz. The method reduces data acquisition times by more than an order of magnitude compared to conventional electro-optic sampling using a scanning delay stage. The approach illustrates the wide applicability of the single-shot measurement approach to non-equilibrium systems that are studied through OPTP spectroscopy, especially in cases where parameters such as magnetic field strength (B) or other experimental parameters are varied. We demonstrate the capabilities of our measurement by performing cyclotron resonance experiments in bulk silicon, where we observe B-field-dependent carrier relaxation and distinct relaxation rates for different carrier types. We use a pair of economical linear array detectors to measure 500 time points on each shot, offering an equivalent performance to camera-based detection with possibilities for higher repetition rates.

Instruments & Instrumentation↗