Search NASA⌕ Search

Engineering topics

Zhao, Jun

Publications and source records attributed to Zhao, Jun.

24 records · Page 2

Magnetic Order and Its Interplay with Structure Phase Transition in van der Waals Ferromagnet VI 3

We show that Van der Waals magnet VI 3 demonstrates intriguing magnetic properties that render it great for use in various applications. However, its microscopic magnetic structure has not been determined yet. Here, we report neutron diffraction and susceptibility measurements in VI 3 that revealed a ferromagnetic order with the moment direction tilted from the c-axis by ~36° at 4 K. A spin reorientation accompanied by a structure distortion within the honeycomb plane is observed, before the magnetic order completely disappears at $T_C$ = 50 K. The refined magnetic moment of ~1.3$μ_B$ at 4 K is much lower than the fully ordered spin moment of 2$μ_B$/V 3+ , suggesting the presence of a considerable orbital moment antiparallel to the spin moment and strong spin–orbit coupling in VI 3 . This results in strong magnetoelastic interactions that make the magnetic properties of VI 3 easily tunable via strain and pressure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lithium Deposition-Induced Fracture of Carbon Nanotubes and Its Implication to Solid-State Batteries

The increasing demand for safe and dense energy storage has shifted research focus from liquid electrolyte-based Li-ion batteries toward solid-state batteries (SSBs). However, the application of SSBs is impeded by uncontrollable Li dendrite growth and short circuiting, the mechanism of which remains elusive. Herein, we conceptualize a scheme to visualize Li deposition in the confined space inside carbon nanotubes (CNTs) to mimic Li deposition dynamics inside solid electrolyte (SE) cracks, where the high-strength CNT walls mimic the mechanically strong SEs. We observed that the deposited Li propagates as a creeping solid in the CNTs, presenting an effective pathway for stress relaxation. When the stress-relaxation pathway is blocked, the Li deposition-induced stress reaches the gigapascal level and causes CNT fracture. Mechanics analysis suggests that interfacial lithiophilicity critically governs Li deposition dynamics and stress relaxation. Furthermore, our study offers critical strategies for suppressing Li dendritic growth and constructing high-energy-density, electrochemically and mechanically robust SSBs.

25 ENERGY STORAGE↗

Critical Role of Sc Substitution in Modulating Ferroelectricity in Multiferroic LuFeO 3

Understanding how individual dopants or substitutional atoms interact with host lattices enables us to manipulate, control, and improve the functionality of materials. However, because of the intimate coupling among various degrees of freedom in multiferroics, the atomic-scale influence of individual foreign atoms has remained elusive. Here, we unravel the critical roles of individual Sc substitutional atoms in modulating ferroelectricity at the atomic scale of typical multiferroics, Lu 1–x Sc x FeO 3 , by combining advanced microscopy and theoretical studies. Atomic variations in polar displacement of intriguing topological vortex domains stabilized by Sc substitution are directly correlated with Sc atom-mediated local chemical and electronic fluctuations. The local FeO 5 trimerization magnitude and Lu/Sc–O hybridization strength are found to be significantly reinforced by Sc, clarifying the origin of the strong dependence of improper ferroelectricity on Sc content. We find that this study could pave the way for correlating dopant-regulated atomic-scale local structures with global properties to engineer emergent functionalities of numerous chemically doped functional materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anticoincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) soft x-ray spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS had a square array of 36 x-ray calorimeters at the focal plane. These calorimeters consisted of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector was located behind the calorimeter array and served to reject events due to cosmic rays. We will briefly describe this anticoincidence detector and its performance.

Kilbourne, Caroline A.↗

The Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anti-Coincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS has a square array of 36 microcalorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance.

x-ray calorimeter↗