Thermal effects of an ICL-based mid-infrared CH 4 sensor within a wide atmospheric temperature range

Here, thermal effects of an interband cascade laser (ICL) based mid-infrared methane (CH 4 ) sensor that uses long-path absorption spectroscopy were studied. The sensor performance in the laboratory at a constant temperature of ~ 25°C was measured for 5 hours and its Allan deviation was ~ 2 ppbv with a 1 s averaging time. A LabVIEW-based simulation program was developed to study thermal effects on infrared absorption and a temperature compensation technique was developed to control such effects. An environmental test chamber was employed to investigate thermal effects that occur in the sensor system with variation of the test chamber temperature between 10 and 30°C. The thermal response of the sensor in a laboratory setting was observed using a 2.1 ppm CH 4 standard gas sample. indoor/outdoor CH 4 measurements were conducted to evaluate the sensor performance within a wide atmospheric temperature range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploratory study of atmospheric methane enhancements derived from natural gas use in the Houston urban area

Here, the extensive use of natural gas (NG) in urban areas for heating, cooking and as a vehicular fuel is associated with potentially significant emissions of methane (CH 4 ) to the atmosphere. Methane, a potent greenhouse gas that influences the chemistry of the atmosphere, can be emitted from different sources including leakage from NG infrastructure, transportation activities, end-use uncombusted NG, landfills and livestock. Although significant CH 4 leakage associated with aging local NG distribution systems in the U.S. has been reported, further investigation is required to study the role of this infrastructure component and other NG-related sources in atmospheric CH 4 enhancements in urban centers. In this study, neighborhood-scale mobile-based monitoring of potential CH 4 emissions associated with NG in the Greater Houston area (GHA) is reported. A novel dual-gas 3.337 μm interband cascade laser-based sensor system was developed and mobile-mode deployed for simultaneous CH 4 and ethane (C 2 H 6 ) monitoring during a period of over 14 days, corresponding to ~ 90 hours of effective data collection during summer 2016. The sampling campaign covered ~ 250 road miles and was primarily concentrated on eight residential zones with distinct infrastructure age and NG usage levels. A moderate number of elevated CH 4 concentration events (37 episodes) with mixing ratios not exceeding 3.60 ppmv and associated with atmospheric background enhancements below 1.21 ppmv were observed during the field campaign. Source discrimination analyses based on the covariance between CH 4 and C 2 H 6 levels indicated the predominance of thermogenic sources (e.g., NG) in the elevated CH 4 concentration episodes. The volumetric fraction of C 2 H 6 in the sources associated with the thermogenic CH 4 spikes varied between 2.7 and 5.9%, concurring with the C 2 H 6 content in NG distributed in the GHA. Isolated CH 4 peak events with significantly higher C 2 H 6 enhancements (~11 %) were observed at industrial areas and locations with high density of petroleum and gas pipelines in the GHA, indicating potential variability in Houston’s thermogenic CH 4 sources.

03 NATURAL GAS↗

Ppb-level mid-infrared ethane detection based on three measurement schemes using a 3.34-μm continuous-wave interband cascade laser

A ppb-level mid-infrared ethane (C 2 H 6 ) sensor was developed using a continuous-wave, thermoelectrically cooled, distributed feedback interband cascade laser emitting at 3.34 μm and a miniature dense patterned multipass gas cell with a 54.6-m optical path length. The performance of the sensor was investigated using two different techniques based on the tunable interband cascade laser: direct absorption spectroscopy (DAS) and second-harmonic wavelength modulation spectroscopy (2f-WMS). Three measurement schemes, DAS, WMS and quasi-simultaneous DAS and WMS, were realized based on the same optical sensor core. A detection limit of ~7.92 ppbv with a precision of ±30 ppbv for the separate DAS scheme with an averaging time of 1 s and a detection limit of ~1.19 ppbv with a precision of about ±4 ppbv for the separate WMS scheme with a 4-s averaging time were achieved. An Allan–Werle variance analysis indicated that the precisions can be further improved to 777 pptv @ 166 s for the separate DAS scheme and 269 pptv @ 108 s for the WMS scheme, respectively. For the quasi-simultaneous DAS and WMS scheme, both the 2f signal and the direct absorption signal were simultaneously extracted using a LabVIEW platform, and four C 2 H 6 samples (0, 30, 60 and 90 ppbv with nitrogen as the balance gas) were used as the target gases to assess the sensor performance. A detailed comparison of the three measurement schemes is reported. Here, atmospheric C 2 H 6 measurements on the Rice University campus and a field test at a compressed natural gas station in Houston, TX, were conducted to evaluate the performance of the sensor system as a robust and reliable field-deployable sensor system.

47 OTHER INSTRUMENTATION↗

Compact TDLAS based optical sensor for ppb-level ethane detection by use of a 3.34 μm room-temperature CW interband cascade laser

A mid-infrared ethane (C 2 H 6 ) sensor based on a wavelength modulation spectroscopy (WMS) technique was developed using a thermoelectrically cooled (TEC), continuous-wave (CW) interband cascade laser (ICL) emitting at 3.34 μm and a dense multi-pass gas cell (MPGC, 17 × 6.5 × 5.5 cm 3 ) with a 54.6 m optical path length. A compact optical sensor system with a physical size of 35.5 × 18 × 12.5 cm 3 was designed and constructed. An ICL was employed for targeting a strong C 2 H 6 line at 2996.88 cm -1 at <100 Torr gas pressure in the fundamental absorption band of C 2 H 6 . The sensor performance, including the minimum detection limit (MDL) and the stability were improved by reducing the effect of laser power drift by means of the 2f/1f-WMS technique. A MDL of ~1.2 parts per billion (ppbv) for 2f-WMS and ~1.0 ppbv for 2f/1f-WMS were achieved, respectively, with a measurement time of 4 s. The MDL was further improved from 299 pptv (@108 s for 2f-WMS) to 239 pptv (@208 s for 2f/1f-WMS), based on an Allan deviation analysis.The rise time (@0 → 100 ppbv) and fall time (@100 → 0 ppbv) were determined to be ~64 s and ~48 s,respectively, at a gas pressure of <100 Torr for the C 2 H 6 sensor operation.

03 NATURAL GAS↗