Electron Target Cooling Analyses of the KIPT ADS Using MCNP and Ansys Fluent

This study presents multiphysics analyses of the electron target cooling system of the accelerator-driven system (ADS) of the Kharkiv Institute of Physics and Technology (KIPT) using MCNP and Fluent computer programs. MCNP has been used to transport electrons, gammas, and neutrons, and to calculate the energy deposition in the target materials. The MCNP mesh-tally data have been imported into Fluent by a C subroutine that has been compiled and linked to Fluent as a user-defined function.The KIPT ADS is located in Ukraine and was in operation until February 2022. The Fluent model is based on the computer-aided design files from the manufacturing process of the target assembly. Here, the Fluent results for the reference case match very well the literature results obtained by STAR-CCM+ during the design phase. Other cases that differ from the reference one have been analyzed; in these cases, it is assumed a malfunction of the electron accelerator or of the water cooling system. The target cooling system operates normally for all the analyzed cases except when the inlet water mass flow rate is decreased. The transient analysis showed that the target cooling system can operate for 180 s with full power when the inlet water mass flow rate is decreased down by 75%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical Design of $\mathrm{DEI/ABI}$ System at the $\mathrm{HEX}$ Beamline at the $\mathrm{NSLS-II}$

Diffraction Enhanced Imaging (DEI) or Analyzer Based Imaging (ABI) uses a perfect crystal monochromator and matching analyzer to achieve sensitivity to x-ray refraction and ultra small-angle scattering on the order of 0.01 micro-radians. As such, a thermal bump caused by heat-load in the order of 1 W is detrimental. The heat load at the HEX (High Energy Engineering X-ray) super-conducting wiggler (SCW) beamline, under construction at the NSLS-II, is on the order of 1 kW. How to reconcile the three orders of magnitude difference between the HEX source power and the DEI/ABI requirements? The solution involves using a double-crystal bent-Laue monochromator as pre-monochromator to prepare a beam with a large divergence and bandwidth that is matched to a flat crystal post-monochromator. We show through phase-space (x-ray energy vs. angle as viewed by a flat crystal) analysis and Dumond diagrams that there is indeed a unique bending radius that matches the double-crystal bent-Laue monochromator in phase space to the flat Bragg crystal. The matched system has a desirable feature that the phase space of the bent crystal’s output beam is much larger than that of the flat crystal, making the combined system stable. Based on these considerations, here we present our optical design for performing DEI/ABI at the HEX beamline

36 MATERIALS SCIENCE↗

Proton irradiation effects in Molybdenum-Carbide-Graphite composites

The High Luminosity upgrade of the Large Hadron Collider (HL-LHC) has prompted the investigation of novel materials for beam-intercepting devices, and in particular for the collimators responsible for protecting the machine from beam losses. The HL-LHC collimation system will inevitably experience increased levels of radiation damage and undergo changes in their crucial physio-mechanical properties. Graphite-matrix composite materials containing molybdenum carbide particles, along with small amounts of titanium carbide, were developed with the objective of enhanced in-beam performance and tested under proton irradiation. The physical degradation observed in early grades of molybdenum carbide compounds, even after modest proton fluences, has prompted the development of advanced compounds. In this work, we examine the effects of proton irradiation on the microstructural and thermophysical properties of new grades of Molybdenum-carbide-graphite compounds up to fluences of ~2 × 10 20 p/cm 2 . Here, we employ a combination of precision dilatometry and high-energy X-ray diffraction to quantify the dimensional stability and crystallographic phase evolution both pre- and post-irradiation. Our results reveal that these new compounds exhibit superior resilience to radiation damage than their predecessors.

36 MATERIALS SCIENCE↗

Analysis of ZPPR-15 experimental data for VTR software validation

As part of the Versatile Test Reactor (VTR) program, extensive validation work is being performed to demonstrate the fidelity of the Argonne Reactor Code (ARC) software package presently used for the core design studies. It is anticipated that this software will be also used for initial operations although additional software may be introduced at a later time to supplement or replace some components. The validation work was focused on accumulating reactor models that are consistent with the VTR and thus can be used to validate the accuracy of predictions made by the software used to design and operate the VTR. The U.S. does not have any active experimental facilities that can neutronically mockup the VTR core design. However, in the past, the U.S. had extensive experimental facilities for fast reactor neutronics. In that regard, the ZPPR-15 experiments carried out at ANL during the 1980s work best because the fuel form is closest to the VTR design, there is a considerable amount of processed data available for use, and existing staff are already familiar with the experimental machine and measurements. Because of previous collaborative work, many of the ZPPR-15 loadings of interest have already been processed into MCNP and preliminary ARC models, and a full uncertainty quantification has already been completed for many of the ZPPR-15 measurements. This manuscript covers the recent analysis work on the ZPPR-15 experiments and compares it with the experimental results. With respect to the ARC software components, this manuscript focuses on validation of the MC 2 , DIF3D and GAMSOR using the ZPPR-15 experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation damage of a two-dimensional carbon fiber composite (CFC)

Carbon fiber composites (CFC) are, among other applications, already in use as low-impedance collimating elements for intercepting TeV-level protons machines, like the CERN Large Hadron Collider. Towards a comprehensive understanding of these materials’ properties and behavior, a series of radiation damage campaigns have been undertaken in order to quantitively investigate the response of AC-150 K CFC to high proton fluences. The CFCs dimensional changes, stability, micro-structural evolution, and structural integrity below and above 5 × 10 20 p/cm 2 fluence threshold were studied. The irradiating particles were protons of kinetic energies in the range of 130–200 MeV. The effects of the irradiation temperature (~90–180°C and 280–500°C) combined with the proton fluence on the dimensional stability and the microstructural evolution of this anisotropic two-dimensional composite structure were studied using precision dilatometry and X-ray diffraction. Our results shed light on the fluence-based limitations for these composite materials. Furthermore, we compare these results with reference unirradiated graphite, and we discuss the similarities and differences in the dimensional changes and post-irradiation annealing properties.

36 MATERIALS SCIENCE↗

A new generation of direct X-ray detectors for medical and synchrotron imaging applications

Abstract Large-area X-ray imaging is one of the most widely used imaging modalities that spans several scientific and technological fields. Currently, the direct X-ray conversion materials that are being commercially used for large-area (> 8 cm × 4 cm without tiling) flat panel applications, such as amorphous selenium (a-Se), have usable sensitivities of up to only 30 keV. Although there have been many promising candidates (such as polycrystalline HgI 2 and CdTe), none of the semiconductors were able to assuage the requirement for high energy (> 40 keV) large-area X-ray imaging applications due to inadequate cost, manufacturability, and long-term performance metrics. In this study, we successfully demonstrate the potential of the hybrid Methylammonium lead iodide (MAPbI 3 ) perovskite-based semiconductor detectors in satisfying all the requirements for its successful commercialization in synchrotron and medical imaging. This new generation of hybrid detectors demonstrates low dark current under electric fields needed for high sensitivity X-ray imaging applications. The detectors have a linear response to X-ray energy and applied bias, no polarization effects at a moderate bias, and signal stability over long usage durations. Also, these detectors have demonstrated a stable detection response under BNL’s National Synchrotron Light Source II (NSLS-II) 70 keV monochromatic synchrotron beamline.

47 OTHER INSTRUMENTATION↗