Search NASA⌕ Search

Engineering topics

Zhou, D.

Publications and source records attributed to Zhou, D..

Coherent wiggler radiation impedance at the storage ring cooler for the EIC project

The Electron Ion Collider project is presently under design at Brookhaven National Laboratory. One of the options how to achieve an electron-proton high-luminosity of 10 34 cm –2 s –1 range, is the storage ring cooler concept, which is based on employing a significant amount of the damping wigglers. One of the main concerns, in achieving the required beam parameters, is the collective effects, especially the coherent synchrotron radiation impedance produced by the damping wigglers and its effect on the longitudinal beam dynamics. Low energy of the electrons, E o =149.6 MeV, small vacuum chamber aperture, b=15 mm, small bending radius and a big number of poles make the coherent synchrotron radiation simulations for the damping wiggler with D. Zhou’s CSRZ code, pretty challenging. The obtained numerical results have been compare with a theoretical approach of Stupakov and Zhou. The strong narrow-band impedance, due to a presence of the periodic poles and the vacuum chamber, have been identified and classified. To suppress or detune the high-Q resonance peaks, a design of the damping wiggler with a varied period of length is presented and discussed.

43 PARTICLE ACCELERATORS↗

Design of beam optics for the future circular collider e + e - collider rings

A beam optics scheme has been designed for the future circular collider- e + e - (FCC-ee). The main characteristics of the design are: beam energy 45 to 175 GeV, 100 km circumference with two interaction points (IPs) per ring, horizontal crossing angle of 30 mrad at the IP and the crab-waist scheme [P. Raimondi, D. Shatilov, and M. Zobov, arXiv:physics/0702033; P. Raimondi, M. Zobov, and D. Shatilov, in Proceedings of the 22nd Particle Accelerator Conference, PAC-2007, Albuquerque, NM (IEEE, New York, 2007), p. TUPAN037.] with local chromaticity correction. The crab-waist scheme is implemented within the local chromaticity correction system without additional sextupoles, by reducing the strength of one of the two sextupoles for vertical chromatic correction at each side of the IP. So-called “tapering” of the magnets is applied, which scales all fields of the magnets according to the local beam energy to compensate for the effect of synchrotron radiation (SR) loss along the ring. An asymmetric layout near the interaction region reduces the critical energy of SR photons on the incoming side of the IP to values below 100 keV, while matching the geometry to the beam line of the FCC proton collider (FCC-hh) [A. Chancé et al., Proceedings of IPAC’16, 9–13 May 2016, Busan, Korea, TUPMW020 (2016).] as closely as possible. Sufficient transverse/longitudinal dynamic aperture (DA) has been obtained, including major dynamical effects, to assure an adequate beam lifetime in the presence of beamstrahlung and top-up injection. In particular, a momentum acceptance larger than ±2% has been obtained, which is better than the momentum acceptance of typical collider rings by about a factor of 2. The effects of the detector solenoids including their compensation elements are taken into account as well as synchrotron radiation in all magnets. The optics presented in this study is a step toward a full conceptual design for the collider. Finally, a number of issues have been identified for further study.

43 PARTICLE ACCELERATORS↗

Substrate temperature controls molecular orientation in two-component vapor-deposited glasses

Vapor-deposited glasses can be anisotropic and molecular orientation is important for organic electronics applications. In organic light emitting diodes (OLEDs), for example, the orientation of dye molecules in two-component emitting layers significantly influences emission efficiency. Here we investigate how substrate temperature during vapor deposition influences the orientation of dye molecules in a model two-component system. We determine the average orientation of a linear blue light emitter 1,4-di-[4-( N,N -diphenyl)amino]styrylbenzene (DSA-Ph) in mixtures with aluminum-tris(8-hydroxyquinoline) (Alq 3 ) by spectroscopic ellipsometry and IR dichroism. We find that molecular orientation is controlled by the ratio of the substrate temperature during deposition and the glass transition temperature of the mixture. Furthermore, these findings extend recent results for single component vapor-deposited glasses and suggest that, during vapor deposition, surface mobility allows partial equilibration towards orientations preferred at the free surface of the equilibrium liquid.

36 MATERIALS SCIENCE↗

Magnetic structure and phase transition of Ni 2 Mn 1.48 Sb 0.52 magnetic shape memory compound

Here, a comprehensive study of the structural and magnetic properties of the Ni 2 Mn 1.48 Sb 0.52 compound is presente using neutron diffraction and magnetic measurements. It is found that Mn atoms on 4a and 4 sites are ferrimagnetic coupled in the austenitic phase. At 300 K, the magnetic moments of Mn (4a) an Mn (4b) are determined to be 2.72(3) μ B and -2.67(5) μ B , respectively. From 260 K to 4 K, the compound is in martensite phase and the magnetic moments of Mn (2a), Mn (2f), Mn (2b), Mn (2e) at 4 K ar 2.2(5) μ B , 2.3(5) μ B , -2.1(5) μ B , and -2.6(5) μ B , respectively.

36 MATERIALS SCIENCE↗

Structural basis for PECAM-1 homophilic binding

Platelet endothelial cell adhesion molecule-1 (PECAM-1) is a 130-kDa member of the immunoglobulin gene superfamily (IgSF) that is present on the surface of circulating platelets and leukocytes, and highly expressed at the junctions of confluent endothelial cell monolayers. PECAM-1–mediated homophilic interactions, known to be mediated by its 2 amino-terminal immunoglobulin homology domains, are essential for concentrating PECAM-1 at endothelial cell intercellular junctions, where it functions to facilitate diapedesis, maintain vascular integrity, and transmit survival signals into the cell. Given the importance of PECAM-1–mediated homophilic interactions in mediating each of these cell physiological events, and to reveal the nature and orientation of the PECAM-1–PECAM-1 homophilic-binding interface, we undertook studies aimed at determining the crystal structure of the PECAM-1 homophilic-binding domain, which is composed of amino-terminal immunoglobulin homology domains 1 and 2 (IgD1 and IgD2). The crystal structure revealed that both IgD1 and IgD2 exhibit a classical IgSF fold, having a β-sandwich topology formed by 2 sheets of antiparallel β strands stabilized by the hallmark disulfide bond between the B and F strands. Interestingly, despite previous assignment to the C2 class of immunoglobulin-like domains, the structure of IgD1 reveals that it actually belongs to the I2 set of IgSF folds. Both IgD1 and IgD2 participate importantly in the formation of the trans homophilic-binding interface, with a total buried interface area of >2300 Å 2 . These and other unique structural features of PECAM-1 allow for the development of an atomic-level model of the interactions that PECAM-1 forms during assembly of endothelial cell intercellular junctions.

59 BASIC BIOLOGICAL SCIENCES↗

Multicaloric effect in bi-layer multiferroic composites

The multicaloric effect was theoretically proposed in 2012 and, despite numerous follow up studies, the effect still awaits experimental confirmation. The main limitation is the fact that the multicaloric effect is only observed at a temperature equal to the transition temperature of the magnetic and electric phases coexisting within a multiferroic (MF) (i.e., T ≈ T{sub c}{sup m} ≈ T{sub c}{sup e}). Such condition is hard to fulfill in single phase MFs and a solution is to develop suitable composite MF materials. Here, we examine the multicaloric effect in a bi-layer laminated composite MF in order to determine the optimal design parameters for best caloric response. We show that magnetically induced multicaloric effect requires magnetic component of heat capacity smaller than that of the electric phase, while the layer thickness of the magnetic phase must be at least 5 times the thickness of the electric phase. The electrically induced multicaloric effect requires the magnetic layer to be 10% of the electric phase thickness, while its heat capacity must be larger than that of the electric phase. These selection rules are generally applicable to bulk as well as thin film MF composites for optimal multicaloric effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensor System Performance Evaluation and Benefits from the NPOESS Airborne Sounder Testbed-Interferometer (NAST-I)

Advanced satellite sensors are tasked with improving global-scale measurements of the Earth's atmosphere, clouds, and surface to enable enhancements in weather prediction, climate monitoring, and environmental change detection. Validation of the entire measurement system is crucial to achieving this goal and thus maximizing research and operational utility of resultant data. Field campaigns employing satellite under-flights with well-calibrated FTS sensors aboard high-altitude aircraft are an essential part of this validation task. The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed-Interferometer (NAST-I) has been a fundamental contributor in this area by providing coincident high spectral/spatial resolution observations of infrared spectral radiances along with independently-retrieved geophysical products for comparison with like products from satellite sensors being validated. This paper focuses on some of the challenges associated with validating advanced atmospheric sounders and the benefits obtained from employing airborne interferometers such as the NAST-I. Select results from underflights of the Aqua Atmospheric InfraRed Sounder (AIRS) and the Infrared Atmospheric Sounding Interferometer (IASI) obtained during recent field campaigns will be presented.

Larar, A.↗

EAQUATE: An International Experiment for Hyper-Spectral Atmospheric Sounding Validation

The international experiment called EAQUATE (European AQUA Thermodynamic Experiment) was held in September 2004 in Italy and the United Kingdom to demonstrate certain ground-based and airborne systems useful for validating hyperspectral satellite sounding observations. A range of flights over land and marine surfaces were conducted to coincide with overpasses of the AIRS instrument on the EOS Aqua platform. Direct radiance evaluation of AIRS using NAST-I and SHIS has shown excellent agreement. Comparisons of level 2 retrievals of temperature and water vapor from AIRS and NAST-I validated against high quality lidar and drop sonde data show that the 1K/1km and 10%/1km requirements for temperature and water vapor (respectively) are generally being met. The EAQUATE campaign has proven the need for synergistic measurements from a range of observing systems for satellite cal/val and has paved the way for future cal/val activities in support of IASI on the European Metop platform and CrIS on the US NPP/NPOESS platform.

Taylor, J. P.↗

Recent Low-Earth Orbit Radiation Measurements Using Passive Dosimeters during ISS Expeditions 13, 14 and 15

Current passive radiation measurements in low-Earth orbit (LEO) involve using a combination of thermally/optically stimulated luminescence detectors (TLDs/OSLDs) for the low-LET component (LET<10 keV/micron water) of the space radiation field and plastic nuclear track detectors (PNTDs) for the high-LET region (LET>10 keV/micron water), as per National Council on Radiation Protection recommendation (NCRP 132, 2004). This combination of radiation detectors has been successfully implemented at NASA Johnson Space Center for routine crewmember and ISS area monitoring using LiF:Mg,Ti, CaF2:Tm, Al2O3:C and CR-39 material. This paper will present in detail the measurement and data processing techniques employed for passive space radiation measurements by the Space Radiation Analysis Group (SRAG) at JSC. The paper will also summarize the absorbed dose, dose equivalent and quality factor results for the area monitoring during ISS Expeditions 13, 14 and 15.

Gaza, R.↗

Radiation Measured during ISS-Expedition 13 with Different Dosimeters

Radiation in low Earth orbit (LEO) is mainly composed of Galactic Cosmic Rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors in various configurations; the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation exposure for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the operational principles for the dosimeters, describes the method to combine the results measured by TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured. Keywords: space radiation; cosmic rays; active and passive dosimeters; LET spectra

Zhou, D.↗

Radiation measured with TEPC and CR-39 PNTDs in low Earth orbit

The radiation impact to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to investigate the LET spectrum for the radiation field in low Earth orbit (LEO) and the influence of radiation on astronauts. The best active dosimeter used for all LET is the tissue equivalent proportional counter (TEPC); the best passive dosimeter used for high LET is CR-39 plastic nuclear track dosimeter (PNTD). TEPC and CR-39 PNTDs were used to investigate the radiation in LEO. LET spectra and radiation quantities were obtained for STS-112 and STS-114 missions with TEPC and CR-39 PNTDs. This paper introduces the operation principles for the two types of dosimeters, presents radiation results measured and compares the results obtained with different dosimeters.

Zhou, D.↗