Search NASA⌕ Search

Engineering topics

Zhu, Xun

Publications and source records attributed to Zhu, Xun.

Diagnosis of Middle Atmosphere Climate Sensitivity by the Climate Feedback Response Analysis Method

We present a new method to diagnose the middle atmosphere climate sensitivity by extending the Climate Feedback-Response Analysis Method (CFRAM) for the coupled atmosphere-surface system to the middle atmosphere. The Middle atmosphere CFRAM (MCFRAM) is built on the atmospheric energy equation per unit mass with radiative heating and cooling rates as its major thermal energy sources. MCFRAM preserves the CFRAM unique feature of an additive property for which the sum of all partial temperature changes due to variations in external forcing and feedback processes equals the observed temperature change. In addition, MCFRAM establishes a physical relationship of radiative damping between the energy perturbations associated with various feedback processes and temperature perturbations associated with thermal responses. MCFRAM is applied to both measurements and model output fields to diagnose the middle atmosphere climate sensitivity. It is found that the largest component of the middle atmosphere temperature response to the 11-year solar cycle (solar maximum vs. solar minimum) is directly from the partial temperature change due to the variation of the input solar flux. Increasing CO2 always cools the middle atmosphere with time whereas partial temperature change due to O3 variation could be either positive or negative. The partial temperature changes due to different feedbacks show distinctly different spatial patterns. The thermally driven globally averaged partial temperature change due to all radiative processes is approximately equal to the observed temperature change, ranging from 0.5 K near 70 km from the near solar maximum to the solar minimum.

MCFRAM↗

Comparison of daily averaged reflection, transmission, and absorption for selected radiative flux transfer approximations

This paper compares accuracy for the daily averaged reflection, transmission, and absorption of solar flux derived from the delta-four-stream approximation and a few selected two-stream approximations. In the chosen variety of two-stream approximations, a two-stream approximation suggested by Zhu produces the most accurate reflection and transmission for conservative scattering with optical thickness tau(sub 1) less than 3. Otherwise, the delta-Eddington approximation is superior to other two-stream approximations. The delta-four stream approximation produces errors that are smaller than the delta-Eddington approximation by at least a factor of 2.

Zhu, Xun↗

Detection of the SO2 atmosphere on Io with the Hubble Space Telescope

Observations of the trailing hemisphere of Io made with the Faint Object Spectrograph of the Hubble Space Telescope (HST) in March 1992 have resulted in the first detection of atmospheric SO2 absorption bands in the ultraviolet. These observations represent only the third positive means of detection of what is widely believed to be Io's primary atmospheric constituent. Below approximately 2130 A the geometric albedo of the satellite is dominated by SO2 gas absorption band signatures, which have been analyzed using models that include the effects of optical thickness, temperature, and spatial distribution. The disk-intergrated HST data cannot resolve the spatial distribution, but it is possible to define basic properties and set constraints on the atmosphere at the time of the observations. Hemispheric atmospheres with average column density N = 6 - 10 x 10(exp 15)/sq sm and T(gas) = 110 - 500 K fit the data, with preference for temperatures of approximately 200 - 250 K. Better fits are found as the atmosphere is spatially confined, with a limit of approximately 8% hemispheric areal coverage and N approximately equal to 3 x 10(exp 17)/sq cm with colder 110 - 250 K temepratures. A dense (N greater than or equal to 10(exp 16)/sq cm), localized component of SO2 gas, such as that possibly associated with active volcanoes, can generate the observed spectral constrast only when the atmosphere is cold (110 K) and an extended component such as Pele is included. The combination of a dense, localized atmosphere with a tenuous component (N less than 10(exp 16)/sq cm, either patchy or extended) also fits the data. In all cases the best fit models imply a disk-averaged column density larger than exospheric but approximately 10 - 30 times less than the previous upper limit from near-UV observations.

Ballester, G. E.↗

On the vertical thermal structure of Io's atmosphere

A radiative-thermal conduction model for the vertical thermal structure of Io's atmosphere is developed with solar heating by SO2 absorption in UV and near-IR bands and non-local thermodynamic equilibrium (LTE) cooling by SO2 nu(sub 1), nu(sub 2), nu(sub 3), vibrational bands and rotational lines. The model predicts the existence of a mesopause in Io's atmosphere when the surface pressure exceeds approximately 10 nbar. The radiative time constant for establishing a mesosphere/mesopause on Io is only approximately 20 min, whereas the thermospheric radiative time constant is about 1 hr. These time constants are significantly shorter than the diurnal time scale and competitive with dynamic time scales. In the thermosphere when solar UV heating dominates, the asymptotic thermospheric temperature is approximately 270 K, only 140 K greater than the surface temperature because at high altiudes non-LTE cooling by SO2 rotation lines exceeds cooling in the nu(sub 2) virbrational band. Solar-heating-only modles are incapable of generating warm enough atmospheres to satisfy the observational inferences from UV and especially millimeter-wave meausrements. Joule heating driven by the penetration of Jupiter's corotational electric field into Io's conducting ionosphere is demonstrated to be the dominant heating mechanism in the subnanobar regions of Io's atmosphere with tempertures ranging from 150 to 1000 K as a function of decreasing pressure from 1 to 0.1 nbar, The asymoptotic thermospheric temperature can attain a value as high as 1800 K.

Strobel, Darrell F.↗

Upper limit on Titan's atmospheric argon abundance

An analysis is conducted on the Voyager 1 UV Spectrometer solar-occultation data and a Titan flyby spectrum of the north polar region dayglow, in order to infer the tropopausal Ar mixing ratio's upper limit as a function of the CH4 mixing ratio, f(CH4). The mole-fraction upper limit of tropopausal Ar mixing ratio ranges from 0.01 to 0.1 at f(CH4) of 0.026 to as low as 0.08 at f(CH4) of 0.05. Since the best fits to the solar occultation data require f(CH4) of more than 0.26, the Ar mixing ratio must be lower than 0.1.

Strobel, Darrell F.↗

Titan's upper atmosphere - Structure and ultraviolet emissions

An analysis is conducted of the composition and thermal structure of Titan's upper atmosphere, and the relative importance of airglow-excitation processes, on the basis of Voyager 1 UV spectrometer data for solar occultation and airglow. Attention is also given to the Smith et al. (1982) optical depth profiles for the evening terminator, entrance occultation, and asymptotic temperature. A magnetospheric power input figure is obtained that is 25 times smaller than the initial estimate by Strobel and Shemansky (1982).

Strobel, Darrell F.↗

A model study of the response of mesospheric ozone to short-term solar ultraviolet flux variations

An investigation is conducted in order to determine the relative importance of several modeled processes in controlling the magnitude and phase of the mesospheric ozone response. A detailed one-dimensional modeling study of the mesospheric ozone response to solar UV flux variations is conducted to remove some of the deficiencies in previous studies. This study is also used to examine specifically the importance of solar zenith angle, self-consistent calculation of water vapor abundance, and temperature feedback with a nonlocal thermodynamic equilibrium radiation model. The photochemical model is described, and the assumptions made for the purpose of comparing model results with the observed ozone response obtained from a statistical analysis of Solar Mesosphere Explorer data (Keating et al., 1987) are discussed. The numerical results for the theoretical ozone response are presented. The results of selected time-dependent calculations are considered to illustrate the degree to which a relatively simple model of the mesosphere is able to capture the major characteristics of the observed response.

Summers, M. E.↗

Mean fields induced by local gravity-wave forcing in the middle atmosphere

The role of geostrophic adjustment in the middle atmosphere for given wave packet forcing by a three-dimensional hydrostatic model is examined. It is shown that the induced fields consist of two different kinds of modes. One, produced by forcing vorticity only, is steady quasi-geostrophic flow; this is restricted to the forcing region. The other, produced by both forcing vorticity and forcing divergence, is oscillatory, and is in the form of gravity waves propagating out of the forcing region plus inertial oscillations in the forcing region. The scales and amplitudes of the induced gravity waves are determined by the forcing. For a typical example, a 200 km x 200 km gravity wave packet of momentum flux 0.5 N/sq m absorbed in a layer of 5 km thickness centered near 18 km altitude, the gravity waves spread to a larger region about 1000 km x 1000 km at a level 7 km above the forcing region. At that level, the horizontal and vertical wavelengths of the induced waves are about 300 km and 7 km respectively, and the momentum flux is substantially reduced to 0.0004 N/sq m. The results suggest that geostrophic adjustment processes may play an important role in specifying the gravity wave spectrum in the middle atmosphere.

Zhu, Xun↗

Photochemical damping of inertio-gravity waves

A simple model is developed for the coupling effect of radiative heating and ozone photochemistry on inertio-gravity waves in the region 16-70 km. It is found that the photochemical damping rate is the weighted sum of the rates caused by two individual processes. One, suggested by Craig and Ohring, involves the temperature dependence of ozone reaction rate coefficients; the other, suggested by Leovy, involves the vertical gradient of the ozone mixing ratio. The relative importance of these two processes depends on the ratio of dynamical and chemical relaxation times. Calculations show that the most important region for coupling is near 48 km where the total relaxation time is 8 days for equinox and 6 days for summer midlatitude.

Zhu, Xun↗