Search NASASearch

Engineering topics

Ziemke, Robert A.

Publications and source records attributed to Ziemke, Robert A..

Solar Simulation for the CREST Preflight Thermal-Vacuum Test at B-2

In June 2011, the multi-university sponsored Cosmic Ray Electron Synchrotron Telescope (CREST) has undergone thermal-vacuum qualification testing at the NASA Glenn Research Center (GRC), Plum Brook Station, Sandusky, Ohio. The testing was performed in the B- 2 Space Propulsion Facility vacuum chamber. The CREST was later flown over the Antarctic region as the payload of a stratospheric balloon. Solar simulation was provided by a system of planar infrared lamp arrays specifically designed for CREST. The lamp arrays, in conjunction with a liquid-nitrogen-cooled cryoshroud, achieved the required thermal conditions for the qualification tests. This report focuses on the design and analysis of the planar arrays based on first principles. Computational spreadsheets are included in the report.

Ziemke, Robert A.

Solar Simulation for the CREST Preflight Thermal-Vacuum Test at B-2

In June 2011, the multi-university sponsored Cosmic Ray Electron Synchrotron Telescope (CREST) has undergone thermal-vacuum qualification testing at the NASA Glenn Research Center (GRC), Plum Brook Station, Sandusky, Ohio. The testing was performed in the B-2 Space Propulsion Facility vacuum chamber. The CREST was later flown over the Antarctic region as the payload of a stratospheric balloon. Solar simulation was provided by a system of planar infrared lamp arrays specifically designed for CREST. The lamp arrays, in conjunction with a liquid-nitrogen-cooled cold wall, achieved the required thermal conditions for the qualification tests. The following slides accompanied the presentation of the report entitled Solar Simulation for the CREST Preflight Thermal-Vacuum Test at B-2, at the 27th Aerospace Testing Seminar, October 2012. The presentation described the test article, the test facility capability, the solar simulation requirements, the highlights of the engineering approach, and the results achieved. The presentation was intended to generate interest in the report and in the B-2 test facility.

Ziemke, Robert A.

Correction for Thermal EMFs in Thermocouple Feedthroughs

A straightforward measurement technique provides for correction of thermal-electromotive-force (thermal-EMF) errors introduced by temperature gradients along the pins of non-thermocouple-alloy hermetic feedthrough connectors for thermocouple extension wires that must pass through bulkheads. This technique is an alternative to the traditional technique in which the thermal-EMF errors are eliminated by use of custom-made multipin hermetic feedthrough connectors that contain pins made of the same alloys as those of the thermocouple extension wires. One disadvantage of the traditional technique is that it is expensive and time-consuming to fabricate multipin custom thermocouple connectors. In addition, the thermocouple-alloy pins in these connectors tend to corrode easily and/or tend to be less rugged compared to the non-thermocouple-alloy pins of ordinary connectors. As the number of thermocouples (and thus pins) is increased in a given setup, the magnitude of these disadvantages increases accordingly. The present technique is implemented by means of a little additional hardware and software, the cost of which is more than offset by the savings incurred through the use of ordinary instead of thermocouple connectors. The figure schematically depicts a typical measurement setup to which the technique is applied. The additional hardware includes an isothermal block (made of copper) instrumented with a reference thermocouple and a compensation thermocouple. The reference thermocouple is connected to an external data-acquisition system (DAS) through a two-pin thermocouple-alloy hermetic feedthrough connector, but this is the only such connector in the apparatus. The compensation thermocouple is connected to the DAS through two pins of the same ordinary multipin connector that connects the measurement thermocouples to the DAS.

Ziemke, Robert A.

Infrared Heater Used in Qualification Testing of International Space Station Radiators

Two heat rejection radiator systems for the International Space Station (ISS) have undergone thermal vacuum qualification testing at the NASA Glenn Research Center (GRC), Plum Brook Station, Sandusky, Ohio. The testing was performed in the Space Power Facility (SPF), the largest thermal vacuum chamber in the world. The heat rejection system radiator was tested first; it removes heat from the ISS crew living quarters. The second system tested was the photovoltaic radiator (PVR), which rejects heat from the ISS photovoltaic arrays and the electrical power-conditioning equipment. The testing included thermal cycling, hot- and cold-soaked deployments, thermal gradient deployments, verification of the onboard heater controls, and for the PVR, thermal performance tests with ammonia flow. Both radiator systems are orbital replacement units for ease of replacement on the ISS. One key to the success of these tests was the performance of the infrared heater system. It was used in conjunction with a gaseous-nitrogen-cooled cryoshroud in the SPF vacuum chamber to achieve the required thermal vacuum conditions for the qualification tests. The heater, which was designed specifically for these tests, was highly successful and easily met the test requirements. This report discusses the heating requirements, the heater design features, the design approach, and the mathematical basis of the design.

Ziemke, Robert A.

Improved Capacitive Liquid-Level Probe

Improved capacitive probe designed to measure level of dielectric liquid in tank. In original application, liquid is hydrogen at low temperature, but design principles applicable to measurement of levels of other dielectric liquids in various temperature ranges. Outstanding features of design those making probe insensitive to temperature-induced and other spurious capacitive effects that otherwise distort capacitive liquid-level readings, and those making it possible to calibrate probe mostly by calculation from first principles.

Ziemke, Robert A.

High resolution, high frame rate video technology development plan and the near-term system conceptual design

The objective of the High Resolution, High Frame Rate Video Technology (HHVT) development effort is to provide technology advancements to remove constraints on the amount of high speed, detailed optical data recorded and transmitted for microgravity science and application experiments. These advancements will enable the development of video systems capable of high resolution, high frame rate video data recording, processing, and transmission. Techniques such as multichannel image scan, video parameter tradeoff, and the use of dual recording media were identified as methods of making the most efficient use of the near-term technology.