Search NASA⌕ Search

Engineering topics

Zimmerle, Daniel

Publications and source records attributed to Zimmerle, Daniel.

At least 19 records

Methane Quantification Performance of the Quantitative Optical Gas Imaging (QOGI) System Using Single-Blind Controlled Release Assessment

Quantitative optical gas imaging (QOGI) system can rapidly quantify leaks detected by optical gas imaging (OGI) cameras across the oil and gas supply chain. A comprehensive evaluation of the QOGI system’s quantification capability is needed for the successful adoption of the technology. This study conducted single-blind experiments to examine the quantification performance of the FLIR QL320 QOGI system under near-field conditions at a pseudo-realistic, outdoor, controlled testing facility that mimics upstream and midstream natural gas operations. The study completed 357 individual measurements across 26 controlled releases and 71 camera positions for release rates between 0.1 kg Ch 4 /h and 2.9 kg Ch 4 /h of compressed natural gas (which accounts for more than 90% of typical component-level leaks in several production facilities). The majority (75%) of measurements were within a quantification factor of 3 (quantification error of –67% to 200%) with individual errors between –90% and 831%, which reduced to –79% to +297% when the mean of estimates of the same controlled release from multiple camera positions was considered. Performance improved with increasing release rate, using clear sky as plume background, and at wind speeds ≤1 mph relative to other measurement conditions.

42 ENGINEERING↗

Point Sensor Networks Struggle to Detect and Quantify Short Controlled Releases at Oil and Gas Sites

This study evaluated multiple commercially available continuous monitoring (CM) point sensor network (PSN) solutions under single-blind controlled release testing conducted at operational upstream and midstream oil and natural gas (O&G) sites. During releases, PSNs reported site-level emission rate estimates of 0 kg/h between 38 and 86% of the time. When non-zero site-level emission rate estimates were provided, no linear correlation between the release rate and the reported emission rate estimate was observed. The average, aggregated across all PSN solutions during releases, shows 5% of the mixing ratio readings at downwind sensors were greater than the site’s baseline plus two standard deviations. Four of seven total PSN solutions tested during this field campaign provided site-level emission rate estimates with the site average relative error ranging from −100% to 24% for solution D, −100% to −43% for solution E, −25% for solution F (solution F was only at one site), and −99% to 430% for solution G, with an overall average of −29% across all sites and solutions. Of all the individual site-level emission rate estimates, only 11% were within ±2.5 kg/h of the study team’s best estimate of site-level emissions at the time of the releases.

42 ENGINEERING↗

Load-Packaged AC/DC and DC/DC Power Electronics Converter Performance Data

This data set contains experimentally characterized performance data from load-packaged alternating current to direct current (AC/DC) and direct current to direct current (DC/DC) power electronics converters associated with lighting devices and miscellaneous electrical loads typically found in commercial buildings in the United States. The data set contains input power, output power, efficiency, and harmonic spectrum data for 58 AC/DC converters and 35 DC/DC converters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Harmonic cancellation within AC low voltage distribution for a realistic office environment

An increase of non-linear loads, primarily from power electronics, has substantially increased current harmonics in commercial buildings, which contributes to decreased transformer efficiency / lifespan and poor power quality. This study uses recorded power consumption data from common miscellaneous electric loads (MELs) seen in offices, combined with detailed characterizations of example MELs, to simulate harmonic cancellation within building circuits. Typically, harmonic cancellation studies assume that AC converters operate across their rated power range. However, this study finds that common MELs operate below 40% of rated power the majority of the time when not quiescent; 89% of sampled devices never operated above 60% of rated power. Simulations using these more realistic power levels indicate current-harmonic cancellation (3rd to 13th harmonic) is significantly lower than that predicted when using full-range power assumptions, resulting in minor errors for low-order harmonics and larger errors for higher order harmonics. Furthermore, increased MELs load diversity increases harmonic cancellation, but insufficiently to eliminate errors. In contrast, blending lighting loads with MELs on the secondaries of distribution transformers improves harmonic cancellation to near those predicted by traditional methods. These results indicate that realistic power levels, as well as better characterization of harmonics from typical MELs, should be used to estimate harmonic cancellation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methane Exhaust Measurements at Gathering Compressor Stations in the United States

Unburned methane entrained in exhaust from natural gas-fired compressor engines (“combustion slip”) can account for a substantial portion of station-level methane emissions. A novel in-stack, tracer gas method was coupled with Fourier transform infrared (FTIR) species measurements to quantify combustion slip from natural gas compressor engines at 67 gathering and boosting stations owned or managed by nine “study partner” operators in 11 U.S. states. The mean methane emission rate from 63 four-stroke, lean-burn (4SLB) compressor engines was 5.62 kg/h (95% CI = 5.15–6.17 kg/h) and ranged from 0.3 to 12.6 kg/h. The mean methane emission rate from 39 fourstroke, rich-burn (4SRB) compressor engines was 0.40 kg/h (95% CI = 0.37– 0.42 kg/h) and ranged from 0.01 to 4.5 kg/h. Study results for 4SLB engines were lower than both the U.S. EPA compilation of air pollutant emission factors (AP-42) and Inventory of U.S. Greenhouse Gas Emissions and Sinks (GHGI) by 8 and 9%, respectively. Study results for 4SRB engines were 43% of the AP-42 emission factor and 8% of the GHGI emission factor, the latter of which does not distinguish between engine types. Total annual combustion slip from the U.S. natural gas gathering and boosting sector was modeled using measured emission rates and compressor unit counts from the U.S. EPA Greenhouse Gas Reporting Program. Modeled results [328 Gg/y (95% CI = 235–436 Gg/y) of unburned methane] would account for 24% (95% CI = 17–31%) of the 1391 Gg of methane emissions for “Gathering and Boosting Stations”, or 6% of the net emissions for “Natural Gas Systems” (5598 Gg) as reported in the 2020 U.S. EPA GHGI. In conclusion, gathering and boosting combustion slip emissions reported in the 2020 GHGI (374 Gg) fall within the uncertainty of this model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methane Emissions from Gathering Compressor Stations in the U.S.

Using results from a nationally representative measurement campaign at 180 gathering compressor stations conducted with nine industry partners, this study estimated emissions for the U.S. gathering sector, where sector-specific emission factors have not been previously available. The study drew from a partner station population of 1705 stations—a significantly larger pool than was available for prior studies. Data indicated that whole gas emission rates from components on gathering stations were comparable to or higher than emission factors utilized by the EPA’s greenhouse gas reporting program (GHGRP) but less than emission factors used for similar components on transmission compressor stations. Field data also indicated that the national population of stations likely has a higher fraction of smaller stations, operating at lower throughput per station, than the data used to develop the per-station emission factor used in EPA’s greenhouse gas inventory (GHGI). This was the first national study to incorporate extensive activity data reported to the GHGRP, including 319 basin-level reports, covering 15,895 reported compressors. Further, combining study emission data with 2017 GHGRP activity data, the study indicated statistically lower national emissions of 1290 [1246–1342] Gg methane per year or 66% [64–69%] of current GHGI estimates, despite estimating 17% [12–22%] more stations than the 2017 GHGI (95% confidence interval). Finally, we propose a replicable method that uses GHGRP activity data to annually update GHGI gathering and boost sector emissions.

03 NATURAL GAS↗

Roadmapping Minigrid Innovations for Cost Reduction

Electrification of the world's rural regions is a high priority for both the private and public sectors, as it has been linked to economic development, improved education and public health. Minigrid systems, opposed to grid extension, have been identified as the favorable solution for electrification in many cases. However, the life cycle costs of minigrid systems remain too high for widespread implementation. To address this, Colorado State University (CSU) and the National Renewable Energy Laboratory (NREL) hosted a series of 3 workshops to engage a range of minigrid stakeholders to determine common issues underlying the cost of minigrid systems. The series identified numerous areas for further development in technology and business, with equal emphasis on pre-installation, capital/equipment, and operational costs. In addition, the workshop series emphasized the need for better market intelligence and a better understanding of productive use as a means of stimulating energy demand.

cost reduction↗

Characterization of Methane Emissions from Gathering Compressor Stations (Final Report)

This document is the final report to the U.S. Department of Energy (DOE) for contract DE- FE0029068 awarded to Colorado State University (CSU). CSU and subcontractor AECOM partnered with nine U.S. midstream operators to characterize emissions from natural gas gathering and boosting stations ("gathering stations") – a sector of the natural gas supply chain where few measurements have been made and little data are available for component emissions. Although there is overlap in the classes of equipment on gathering stations with those on production sites or transmission stations that have been measured recently, emissions are likely to differ for functional and operational reasons.

03 NATURAL GAS↗

Data associated with "Methane emissions from gathering and boosting compressor stations in the U.S. Supporting volume 1: Multi-day measurements of pneumatic controller emissions"

This study was part of a larger study (the Gathering Emission Factor, or "GEF") study [1] to develop activity and methane emission factors for EPA's Greenhouse Gas Inventory (EPA GHGI) using direct emission measurements at the device level on all classes of equipment found on gathering compressor stations. To accomplish this, Colorado State University (CSU) partnered with the engineering firm AECOM to assist with planning, logistics, field work and analysis. Nine midstream natural gas companies – Anadarko Petroleum, Equinor, DCP Midstream, Kinder Morgan, MarkWest Energy Partners, Pioneer Natural Resources, Southwestern Energy, Williams Companies Inc., and XTO Energy Inc. – acted as partners in the study, provided site access for measurements, and provided representatives to advisory committees. At all times, and with the encouragement of industry partners, CSU maintained control the sampling plan, analysis and reporting. This study documents one part of the larger study - emissions from pneumatic actuated valve controllers (PC).

03 NATURAL GAS↗

Data associated with, "Methane emissions from gathering and boosting compressor stations in the U.S. Supporting volume 2: Compressor engine exhaust measurements

The in-stack tracer method was used during the field campaign to measure unburned methane entrained in the exhaust of natural gas compressor engines ("combustion slip"). Combustion slipwas estimated by injecting a tracer gas into the exhaust stream at a known flow-rate and measuring concentrations of both the tracer gas and methane at the exhaust stack exit. The total exhaustflow was estimated from the diluted tracer gas concentration measured at the exhaust stack exit.

03 NATURAL GAS↗

Mitigating Communication Delays in Remotely Connected Hardware-in-the-loop Experiments

Here, this paper introduces a potential approach for mitigating the effects of communication delays between multiple, closed-loop hardware-in-the-loop experiments which are virtually connected, yet physically separated. The method consists of an analytical method for the compensation of communication delays, along with the supporting computational and communication infrastructure. The control design leverages tools for the design of observers for the compensation of measurement errors in systems with time-varying delays. The proposed methodology is validated through computer simulation and hardware experimentation connecting hardware-in-the-loop experiments conducted between laboratories separated by a distance of over 100 km.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparing facility-level methane emission rate estimates at natural gas gathering and boosting stations

Coordinated dual-tracer, aircraft-based, and direct component-level measurements were made at midstream natural gas gathering and boosting stations in the Fayetteville shale (Arkansas, USA). On-site component-level measurements were combined with engineering estimates to generate comprehensive facility-level methane emission rate estimates ('study on-site estimates (SOE)') comparable to tracer and aircraft measurements. Combustion slip (unburned fuel entrained in compressor engine exhaust), which was calculated based on 111 recent measurements of representative compressor engines, accounts for an estimated 75% of cumulative SOEs at gathering stations included in comparisons. Measured methane emissions from regenerator vents on glycol dehydrator units were substantially larger than predicted by modelling software; the contribution of dehydrator regenerator vents to the cumulative SOE would increase from 1% to 10% if based on direct measurements. Concurrent measurements at 14 normally-operating facilities show relative agreement between tracer and SOE, but indicate that tracer measurements estimate lower emissions (regression of tracer to SOE = 0.91 (95% CI = 0.83-0.99), R2 = 0.89). Tracer and SOE 95% confidence intervals overlap at 11/14 facilities. Contemporaneous measurements at six facilities suggest that aircraft measurements estimate higher emissions than SOE. Aircraft and study on-site estimate 95% confidence intervals overlap at 3/6 facilities. The average facility level emission rate (FLER) estimated by tracer measurements in this study is 17-73% higher than a prior national study by Marchese et al.

03 NATURAL GAS↗

Comparison of methane emission estimates from multiple measurement techniques at natural gas production pads

This study presents the results of a campaign that estimated methane emissions at 268 gas production facilities in the Fayetteville shale gas play using onsite measurements (261 facilities) and two downwind methods - the dual tracer flux ratio method (Tracer Facility Estimate - TFE, 17 facilities) and the EPA Other Test Method 33a (OTM33A Facility Estimate - OFE, 50 facilities). A study onsite estimate (SOE) for each facility was developed by combining direct measurements and simulation of unmeasured emission sources, using operator activity data and emission data from literature. The SOE spans 0-403 kg/h and simulated methane emissions from liquid unloadings account for 88% of total emissions estimated by the SOE, with 76% (95% CI [51%-92%]) contributed by liquid unloading at two facilities. TFE and SOE show overlapping 95% CI between individual estimates at 15 of 16 (94%) facilities where the measurements were paired, while OFE and SOE show overlapping 95% CI between individual estimates at 28 of 43 (65%) facilities. However, variance-weighted least-squares (VWLS) regressions performed on sets of paired estimates indicate statistically significant differences between methods. The SOE represents a lower bound of emissions at facilities where onsite direct measurements of continuously emitting sources are the primary contributor to the SOE, a sub-selection of facilities which minimizes expected inter-method differences for intermittent pneumatic controllers and the impact of episodically-emitting unloadings. At 9 such facilities, VWLS indicates that TFE estimates systematically higher emissions than SOE (TFE-to-SOE ratio = 1.6, 95% CI [1.2 to 2.1]). At 20 such facilities, VWLS indicates that OFE estimates systematically lower emissions than SOE (OFE-to-SOE ratio of 0.41 [0.26 to 0.90]). Given that SOE at these facilities is a lower limit on emissions, these results indicate that OFE is likely a less accurate method than SOE or TFE for this type of facility.

03 NATURAL GAS↗

Electric Energy Management in the Smart Home: Perspectives on Enabling Technologies and Consumer Behavior

Smart homes hold the potential for increasing energy efficiency, decreasing costs of energy use, decreasing the carbon footprint by including renewable resources, and transforming the role of the occupant. At the crux of the smart home is an efficient electric energy management system that is enabled by emerging technologies in the electric grid and consumer electronics. This article presents a discussion of the state-of-the-art in electricity management in smart homes, the various enabling technologies that will accelerate this concept, and topics around consumer behavior with respect to energy usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗