Search NASA⌕ Search

Engineering topics

Zobec, J.

Publications and source records attributed to Zobec, J..

27 records · Page 2

Measurements of $t\overline tH$ Production and the CP Structure of the Yukawa Interaction between the Higgs Boson and Top Quark in the Diphoton Decay Channel

The first observation of the t t ¯ H process in a single Higgs boson decay channel with the full reconstruction of the final state ( H → γ γ ) is presented, with a significance of 6.6 standard deviations ( σ ). The C P structure of Higgs boson couplings to fermions is measured, resulting in an exclusion of the pure C P -odd structure of the top Yukawa coupling at 3.2 σ . The measurements are based on a sample of proton-proton collisions at a center-of-mass energy s = 13 TeV collected by the CMS detector at the LHC, corresponding to an integrated luminosity of 137 fb – 1 . The cross section times branching fraction of the t t ¯ H process is measured to be σ t t ¯ H B γ γ = 1.56 – 0.32 + 0.34 fb , which is compatible with the standard model prediction of 1.13 – 0.11 + 0.08 fb . The fractional contribution of the C P -odd component is measured to be f C P H t t = 0.00 ± 0.33 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of heavy, energetic, hadronically decaying particles using machine-learning techniques

Machine-learning (ML) techniques are explored to identify and classify hadronic decays of highly Lorentz-boosted W/Z/Higgs bosons and top quarks. Techniques without ML have also been evaluated and are included for comparison. The identification performances of a variety of algorithms are characterized in simulated events and directly compared with data. The algorithms are validated using proton-proton collision data at $\sqrt{s}$ = 13TeV, corresponding to an integrated luminosity of 35.9 fb -1 . Systematic uncertainties are assessed by comparing the results obtained using simulation and collision data. The new techniques studied in this paper provide significant performance improvements over non-ML techniques, reducing the background rate by up to an order of magnitude at the same signal efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of differential cross sections and charge ratios for t -channel single top quark production in proton–proton collisions at $\sqrt{s}=13$ $\,\text {Te}\text {V}$

A measurement is presented of differential cross sections for t-channel single top quark and antiquark production in proton–proton collisions at a centre-of-mass energy of 13$\,\text {Te}\text {V}$ by the CMS experiment at the LHC. From a data set corresponding to an integrated luminosity of 35.9$\,\text {fb}^{-1}$, events containing one muon or electron and two or three jets are analysed. The cross section is measured as a function of the top quark transverse momentum ($p_{\mathrm{T}} $), rapidity, and polarisation angle, the charged lepton $p_{\mathrm{T}} $ and rapidity, and the $p_{\mathrm{T}} $ of the $\text {W}{}{}$ boson from the top quark decay. In addition, the charge ratio is measured differentially as a function of the top quark, charged lepton, and $\text {W}{}{}$ boson kinematic observables. The results are found to be in agreement with standard model predictions using various next-to-leading-order event generators and sets of parton distribution functions. Additionally, the spin asymmetry, sensitive to the top quark polarisation, is determined from the differential distribution of the polarisation angle at parton level to be $0.440 \pm 0.070$, in agreement with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the CMS hadron calorimeters using proton-proton collision data at √ s = 13 TeV

Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities |η| < 3 and are positioned inside the solenoidal magnet. An outer calorimeter, outside the magnet coil, covers |η| < 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to |η| < 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at √ s = 7 , 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb -1 . The intercalibration of channels exploits the approximate uniformity of energy collection over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z→ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗