Search NASA⌕ Search

Engineering topics

Zorn, Gilad

Publications and source records attributed to Zorn, Gilad.

Enhanced Mechanical Properties and Wear Resistance of FeCrAl Alloys at ~ 300°C and Higher Temperatures

Abstract Worldwide, light water reactors (LWRs) have been using zirconium (Zr)-based alloys for the cladding of the uranium dioxide fuel for more than 6 decades. Zr alloys oxidize rapidly in the presence of water and steam at temperatures > 450°C; therefore, they do not respond well to scenarios of loss of coolant accidents. There is a global effort by nuclear materials technologists to find more robust or stronger cladding materials for LWRs. One option is to use an iron-chromium-aluminum (FeCrAl) alloy since they have excellent resistance to high temperature oxidation and superior mechanical properties at LWR operation temperatures. Results show that (1) FeCrAl alloys have better mechanical properties than Zr alloy and are orders of magnitude more resistant to creep at temperatures higher than LWR normal operation conditions. (2) FeCrAl alloys have better resistance to fretting wear than Zr alloys at the normal operation conditions of LWRs.

Materials Science↗

Characterizing the composition, structure, and mechanical properties of magnetron sputtering physical vapor deposition TiN and TiSiN coatings

Ti(Si)N coatings were deposited on Si wafers via magnetron sputtering physical vapor deposition technique. Scanning electron microscopy and atomic force microscopy were used to study the morphologies, grain size, and thicknesses of the different films. X-ray diffraction confirmed the formation of the titanium nitride cubic phase. X-ray photoelectron spectroscopy (XPS) was used to study the silicon and oxygen levels in the films, and high resolution XPS was used to determine the surface oxide to nitride ratios as well as the silicon–nitrogen environment. The hardness of these films was then determined with nanoindentation. It was shown that grain size and film density could be controlled by the Si level and the ion bombardment to eliminate the oxygen level in the nitride coatings, which led to the harder films. It was suggested that due to the miscibility of Si, a ternary TiSiN solid solution was formed. Stronger (200) orientation of the TiN B1-NaCl crystals was associated with increased hardness of the coatings. In conclusion, this crystalline structure was preserved after incorporating Si.

36 MATERIALS SCIENCE↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗