Fabry-Perot/CCD observations of /S III/ and /S II/ emissions from the Jupiter plasma torus
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Zucchino, P..
Explore the source record for details and available documents.
The present investigation is concerned with the suitability of the virtual phase CCD imager for frontside detection of electrons up to 25 keV. The investigation has the objective to determine if the imager can be used in the frontside mode with a photocathode to detect very low light levels in astronomical applications, the ultimate goal being individual photon detection. It is found that the standard virtual phase imager will function properly over an extended period at low levels of 20 kV electron irradiation consistent with photon counting applications. The imager can detect individual primary electrons with nearly 100 percent efficiency. However, further studies are needed to determine the mechanisms for the flat band shifts so that the imager design may be modified to eliminate or at least reduce them.
An experimental version of a thinned illuminated buried-channel 512 x 320 pixel CCD with reduced amplifier input capacitance has been produced which is characterized by lower readout noise. Changes made to the amplifier are discussed, and readout noise measurements obtained by several different techniques are presented. The single energetic electron response of the CCD in the electron-bombarded mode and the single 5.9 keV X-ray pulse height distribution are reported. Results are also given on the dark current versus temperature and the spatial frequency response as a function of signal level.
The recent availability of large format CCD's with high quantum efficiency makes it possible to achieve significant advances in high dispersion astronomical spectroscopy. An echelle CCD combination excels or equals other techniques presently available, and offers the advantage of complete spectral coverage of several thousand Angstroms in a single exposure. Attention is given to experiments which were conducted with a CCD camera head and an echelle spectrograph on a 4-meter telescope. It was found possible to achieve a signal-to-noise ratio of 150/1 on a 13th magnitude star at 6000 A in a two-hour exposure at 0.16 A/pixel, limited primarily by photon statistics. For fainter objects, readout noise is the limiting factor in precision. For 20 electron rms readout noise, an S/N = 15/1 at 18th magnitude is expected, all other things being equal.
A laboratory measurements program was conducted to determine the tolerances that must be imposed to achieve optimum performance from SEC-vidicon data sensors in the LST mission. These measurements along with other data were used to formulate recommendations regarding the necessary telemetry and remote control for the television data sensors when in orbit. The study encompassed the following tasks: (1) Conducted laboratory measurements of the perturbations which an external magnetic field produces on a magnetically focused, SEC-vidicon. Evaluated shielding approaches. (2) Experimentally evaluated the effects produced on overall performance by variations of the tube electrode potentials, and the focus, deflection and alignment fields. (3) Recommended the extent of ground control of camera parameters and camera parameter telemetry required for optimizing the performance of the television system in orbit. The experimental data are summarized in a set of graphs.
Spectra of the radio-quiet quasar PHL 957 were obtained at a 200-in. telescope with a Cassegrain image tube, a Cassegrain multichannel spectrometer, and an integrating television camera on the spectrograph. The image-tube spectra revealed 64 absorption lines between 3200 and 6800 A. The absolute energy distribution indicates that this quasar is one of the most luminous known. The absorption line redshifts and line profiles observed are discussed.
The engineering development of the SEC vidicon as an astronomical sensor has continued in parallel with its operational use. One scientific application was the six hour exposure of the quasar PHL-957 at the Coude spectrograph of the 200-inch Hale telescope. The developmental effort includes both the enhancement of the basic attributes that make the SEC an appropriate sensor, namely, high quantum efficiency, low threshold, and long integration; as well as work to broaden its scientific usefulness, such as the development of a MgF2 photocathode window for vacuum ultraviolet sensitivity, and a permanent magnet focus design for thermal compatibility with proposed large space telescopes. Additional details on the characteristics of the SEC tube are discussed, as well as plans to make a larger and higher resolution version.
Princeton Observatory has been working for several years under NASA sponsorship to develop television type sensors to use in place of photographic film for space astronomy. The performance of an SEC-vidicon with a 25 mm x 25 mm active area, MgF2 window, and bi-alkali photocathode is discussed. Results from ground based use on the Coude spectrograph of the 200-inch Hale telescope are included. The intended use of this tube in an echelle spectrograph sounding rocket payload and on Stratoscope 2 for direct high resolution imagery is also discussed. The paper also discusses the large space telescope image sensor requirements and the development of a larger television tube for this mission.
Princeton Observatory has been working for several years under NASA sponsorship to develop television type sensors to use in place of photographic film for space astronomy. This paper discusses the performance of an SEC-vidicon with a 25 mm x 25 mm active area, MgF2 window, and bi-alkali photocathode. Results from ground based use on the Coude spectrograph of the 200-inch Hale telescope are included. The intended use of this tube in an echelle spectrograph sounding rocket payload and on Stratoscope II for direct high resolution imagery is also discussed. The paper also discusses the Large Space Telescope image sensor requirements and the development of a larger television tube for this mission.
Preamplifier-discriminator-gate generator in printed circuit for use with photomultipliers, noting pulse sensitivity and cost