Search NASA⌕ Search

Engineering topics

Zwaska, R

Publications and source records attributed to Zwaska, R.

Post Irradiation Examination Results of the NT-02 Graphite Fins NuMI Target

The NT-02 neutrino target in the NuMI beamline at Fermilab is a 95 cm long target made up of segmented graphite fins. It is the longest running NuMI target, which operated with a 120 GeV proton beam with maximum power of 340 kW and saw an integrated total proton on target of 6.1 x 10^20. Over the last half of its life, gradual degradation of neutrino yield was observed until the target was replaced. The probable causes for the target performance degradation are attributed to radiation damage, possibly including cracking caused by reduction in thermal shock resistance, as well as potential localized oxidation in the heated region of the target. Understanding the long-term structural response of target materials exposed to proton irradiation is critical as future proton accelerator sources are becoming increasingly more powerful. As a result, an autopsy of the target was carried out to facilitate post-irradiation examination of selected graphite fins. Advanced microstructural imaging and surface elemental analysis techniques were used to characterize the condition of the fins in an effort to identify degradation mechanisms, and the relevant findings are presented in this paper.

Accelerator, Target, Graphite, NuMI, FermiLab, Neu↗

Beam Loss Studies for the 2-MW LBNE Proton Beam Line

Severe limits are put on allowable beam loss during extraction and transport of a 2.3 MW primary proton beam for the Long Baseline Neutrino Experiment (LBNE) at Fermilab. Detailed simulations with the STRUCT and MARS codes have evaluated the impact of beam loss of 1.6 x 10{sup 14} protons per pulse at 120 GeV, ranging from a single pulse full loss to sustained small fractional loss. It is shown that loss of a single beam pulse at 2.3 MW will result in a catastrophic event: beam pipe destruction, damaged magnets and very high levels of residual radiation inside and outside the tunnel. Acceptable beam loss limits have been determined and robust solutions developed to enable efficient proton beam operation under these constraints.

43 PARTICLE ACCELERATORS↗

Electron cloud experiments at Fermilab: Formation and mitigation

We have performed a series of experiments at Fermilab to explore the electron cloud phenomenon. The Main Injector will have its beam intensity increased four-fold in the Project X upgrade, and would be subject to instabilities from the electron cloud. We present measurements of the cloud formation in the Main Injector and experiments with materials for the mitigation of the Cloud. An experimental installation of Titanium-Nitride (TiN) coated beam pipes has been under study in the Main Injector since 2009; this material was directly compared to an adjacent stainless chamber through electron cloud measurement with Retarding Field Analyzers (RFAs). Over the long period of running we were able to observe the secondary electron yield (SEY) change and correlate it with electron fluence, establishing a conditioning history. Additionally, the installation has allowed measurement of the electron energy spectrum, comparison of instrumentation techniques, and energydependent behavior of the electron cloud. Finally, a new installation, developed in conjunction with Cornell and SLAC, will allow direct SEY measurement of material samples irradiated in the accelerator.

43 PARTICLE ACCELERATORS↗

The ecloud measurement setup in the Main Injector

Ecloud has been observed in many high intensity accelerators which can limit the amount of current that can be stored in them. In particular, for ProjectX, the amount of beam current that will be stored in the MI (Main Injector) will be {approx}160 x 10{sup 12} protons while the present maximum intensity is {approx}45 x 10{sup 12} protons which is about 3.5x less beam. Although ecloud has been observed in the MI, it has not caused instabilities at the present running conditions. However, there is no guarantee that instabilities caused by ecloud will not be a problem at ProjectX intensities. Therefore, a program has been started to study the ecloud effects with both computer simulations and experiments. In this paper, we will be focusing our attention on how coatings can affect the production of secondary electrons. We have installed an ecloud measurement setup in a straight section of MI which consists of one coated and one uncoated beam pipe with the same physical dimensions and at the same location, together with four retarding field analyzers (RFAs) and three sets of beam position monitors (BPMs) which can be used for the microwave measurements. An ecloud measurement setup was installed in a straight section of the Main Injector in 2009. The goal of the setup was to compare the characteristics of different beam pipe coatings when subjected to proton beam. The setup consists of one coated and one uncoated beam pipe with the same physical dimensions installed at the same location. Four RFAs (retarding field analyzers) and three BPMs (beam position monitors) used for microwave measurements have been used to measure the ecloud densities. The RFAs have performed very well and have collected both the time evolution and energy distribution of the ecloud for bare and two types of beam pipe coatings.

43 PARTICLE ACCELERATORS↗