Search NASA⌕ Search

Engineering topics

de La Taille, C.

Publications and source records attributed to de La Taille, C..

Timing Performance of the CMS High Granularity Calorimeter Prototype

This paper describes the experience with the calibration,reconstruction and evaluation of the timing capabilities of the CMSHGCAL prototype in the beam tests in 2018. The calibrationprocedure includes multiple steps and corrections ranging from tensof nanoseconds to a few hundred picoseconds. The timing performanceis studied using signals from positron beam particles with energiesbetween 20 GeV and 300 GeV. The performance is studied as afunction of particle energy against an external timing reference aswell as standalone by comparing the two different halves of theprototype. The timing resolution is found to be 60 ps forsingle-channel measurements and better than 20 ps for full showersat the highest energies, setting excellent perspectives for theHGCAL calorimeter performance at the HL-LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-resolution clock phase shifter circuitry for ALTIROC

Abstract A high-resolution clock phase shifter is implemented to adjust the phase of multiple clocks at 40 MHz, 80 MHz, or 640 MHz in the ALTIROC chip. The phase shifter has a coarse-phase shifter and a fine-phase shifter to achieve a step size of 97.7 ps and an adjustable range of 25 ns. The fine delay unit is based on a Delay Locked Loop (DLL) operating at 640 MHz. The phase shifter is fabricated in a 130 nm CMOS process. The area of the phase shifter is 725 µm × 248 µm. The Differential Non-Linearity (DNL) and the Integral Non-Linearity (INL) are ±0.6 LSB and ±0.75 LSB, respectively. The jitter from −25 °C to 20 °C is less than 15.5 ps (RMS), including the contributions from the FPGA clock source and the PLL. The power consumption is 11.2 mW.

Instruments & Instrumentation↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗