Search NASA⌕ Search

Engineering topics

van Genuchten, Case M.

Publications and source records attributed to van Genuchten, Case M..

Groundwater-native Fe(II) oxidation prior to aeration with H 2 O 2 to enhance As(III) removal

Groundwater contaminated with arsenic (As) must be treated prior to drinking, as human exposure to As at toxic levels can cause various diseases including cancer. Conventional aeration-filtration applied to anaerobic arsenite (As(III)) contaminated groundwater can remove As(III) by co-oxidizing native iron (Fe(II)) and As(III) with oxygen (O 2 ). However, the As(III) removal efficiency of conventional aeration can be low, in part, because of incomplete As(III) oxidation to readily-sorbed arsenate (As(V)). In this work, we investigated a new approach to enhance As(III) co-removal with native Fe(II) by the anaerobic addition of hydrogen peroxide (H 2 O 2 ) prior to aeration. Experiments were performed to co-oxidize Fe(II) and As(III) with H 2 O 2 (anaerobically), O 2 (aerobically), and by sequentially adding of H 2 O 2 and O 2 . Aqueous As(III) and As(V) measurements after the reaction were coupled with solid-phase speciation by Fe and As K-edge X-ray absorption spectroscopy (XAS). We found that complete anaerobic oxidation of 100 µM Fe(II) with 100 µM H 2 O 2 resulted in co-removal of 95% of 7 µM As(III) compared to 44% with 8.0-9.0 mg/L dissolved O 2 . Furthermore, we found that with 100 µM Fe(II), the initial Fe(II):H 2 O 2 ratio was a critical parameter to remove 7 µM As(III) to below the 10 µg/L (0.13 µM) WHO guideline, where ratios of 1:4 (mol:mol) Fe(II):H 2 O 2 led to As(III) removal matching that of 7 µM As(V). The improved As(III) removal with H 2 O 2 was found to occur partly because of the well-established enhanced efficiency of As(III) oxidation in Fe(II)+H 2 O 2 systems relatively to Fe(II)+O 2 systems. However, the XAS results unambiguously demonstrated that a large factor in the improved As(III) removal was also due to a systematic decrease in crystallinity, and thus increase in specific surface area, of the generated Fe(III) (oxyhydr)oxides from lepidocrocite in the Fe(II)+O 2 system to poorly-ordered Fe(III) precipitates in the Fe(II)+H 2 O 2 system. The combined roles of H 2 O 2 (enhanced As(III) oxidation and structural modification) can be easily overlooked when only aqueous species are measured, but this dual impact must be considered for accurate predictions of As removal in groundwater treatment.

54 ENVIRONMENTAL SCIENCES↗

Rapid and Efficient Arsenic Removal by Iron Electrocoagulation Enabled with in Situ Generation of Hydrogen Peroxide

Millions of people are exposed to toxic levels of dissolved arsenic in groundwater used for drinking. Iron electrocoagulation (FeEC) has been demonstrated as an effective technology to remove arsenic at an affordable price. However, FeEC requires long operating times (~hours) to remove dissolved arsenic due to inherent kinetics limitations. Air cathode Assisted Iron Electrocoagulation (ACAIE) overcomes this limitation by cathodically generating H 2 O 2 in situ. In ACAIE operation, rapid oxidation of Fe(II) and complete oxidation and removal of As(III) are achieved. Here, we compare FeEC and ACAIE for removing As(III) from an initial concentration of 1464 μg/L, aiming for a final concentration of less than 4 μg/L. We demonstrate that at short electrolysis times (0.5 min), i.e., high charge dosage rates (1200 C/L/min), ACAIE consistently outperformed FeEC in bringing arsenic levels to less than WHO-MCL of 10 μg/L. Using XRD and XAS data, we conclusively show that poor arsenic removal in FeEC arises from incomplete As(III) oxidation, ineffective Fe(II) oxidation and the formation of Fe(II–III) (hydr)oxides at short electrolysis times (<20 min). Finally, we report successful ACAIE performance (retention time 19 s) in removing dissolved arsenic from contaminated groundwater in rural California.

54 ENVIRONMENTAL SCIENCES↗