Search NASA⌕ Search

Engineering topics

von der Linden, J. (ORCID:0000000327477813)

Publications and source records attributed to von der Linden, J. (ORCID:0000000327477813).

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ E × B drift technique (of a $$\sim $$ ∼ 2– $$\upmu $$ μ A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

von der Linden, J. (ORCID:0000000327477813)↗

Annihilation-gamma-based diagnostic techniques for magnetically confined electron–positron pair plasma

Efforts are underway to magnetically confine electron–positron pair plasmas to study their unique behaviour, which is characterized by significant changes in plasma time and length scales, supported waves and unstable modes. However, use of conventional plasma diagnostics presents challenges with these low-density and annihilating matter–antimatter plasmas. To address this problem, we propose to develop techniques based on the distinct emission provided by annihilation. This emission exhibits two spatial correlations: the distance attenuation of isotropic sources and the back-to-back propagation of momentum-preserving 2 $\gamma$ annihilation. We present the results of our analysis of the $\gamma$ emission rate and the spatial profile of the annihilation in a magnetized pair plasma from direct pair collisions, from the formation and decay of positronium as well as from transport processes. In order to demonstrate the effectiveness of annihilation-based techniques, we tested them on annular $\gamma$ emission profiles produced by a $\beta ^+$ radioisotope on a rotating turntable. Direct and positronium-mediated annihilation result in overlapping volumetric $\gamma$ sources, and the 2 $\gamma$ emission from these volumetric sources can be tomographically reconstructed from coincident counts in multiple detectors. Transport processes result in localized annihilation where field lines intersect walls, limiters or internal magnets. These localized sources can be identified by the fractional $\gamma$ counts on spatially distributed detectors.

Physics↗

Confinement of relativistic electrons in a magnetic mirror en route to a magnetized relativistic pair plasma

Creating a magnetized relativistic pair plasma in the laboratory would enable the exploration of unique plasma physics relevant to some of the most energetic events in the universe. As a step toward a laboratory pair plasma, we have demonstrated an effective confinement of multi-MeV electrons inside a pulsed-power-driven 13 T magnetic mirror field with a mirror ratio of 2.6. The confinement is diagnosed by measuring the axial and radial losses with magnetic spectrometers. The loss spectra are consistent with ≤2.5 MeV electrons confined in the mirror for ∼1 ns. With a source of 1012 electron-positron pairs at comparable energies, this magnetic mirror would confine a relativistic pair plasma with Lorentz factor γ∼6 and magnetization σ∼40.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of multilayer-based diagnostics for measurement of high energy x rays and gamma rays

We investigate several possible multilayer-based optic designs for future hard x-ray and gamma ray diagnostics, including the detection and measurement of the positron annihilation radiation at 511 keV. The focus is set on increasing the photon efficiency and signal-to-noise ratio, compared to a previous multilayer-based system that was successfully employed to measure spectra in the 55 keV–100 keV range. Several possible designs using multilayer coatings are discussed, including mirror-based optics and multilayer Laue lenses.

Burcklen, C. (ORCID:0000000271566357)↗