At least 811 records · Page 45

Economic Analysis of On-Route Fast Charging for Battery Electric Buses: Case Study in Utah

Battery electric buses (BEBs) are increasingly being embraced by transit agencies as an energy-efficient and emission-free alternative to bus fleets. However, because of the limitations of battery technology, BEBs suffer from limited driving range, great battery cost, and time-consuming charging processes. On-route fast charging technology is gaining popularity as a remedy, reducing battery cost, extending driving range, and reducing charging time. With on-route fast charging, BEBs are as capable as their diesel counterparts in relation to range and operating time. However, transit agencies may have the following concerns about on-route fast charging: 1) on-route fast charging stations require massive capital costs; 2) on-route fast charging may lead to high electricity power demand charges; and 3) charging during peak hours may increase electricity energy charges. This study conducts a quantitative economic analysis of on-route fast charging for BEBs, thereby providing some guidelines for transit agencies. An integrated optimization model is first proposed to determine battery size, charger type, and recharging schedule for a general BEB route. Based on the model, an economic analysis of on-route fast charging is then performed on 10 real-world bus routes and a simplified general bus route with different parameters. The results demonstrate that given the current prices of on-route fast charging stations and batteries, it is always beneficial to install on-route fast charging stations for BEBs. A sensitivity analysis is also conducted to show the impact of potential price reductions of batteries.

Engineering↗

Battery Deactivation by Electrochemically-Generated Short-Circuit

Every year in the U.S., more than 3,500 people of all ages swallow miniature disc, coin, or “button” batteries. In recent years the number of reported battery ingestions has remained level yet the number of documented debilitating or fatal battery ingestions has increased. One particularly important approach to mitigate this risk is developing a solution that will prevent injury from accidentally swallowed batteries regardless if the ingestion is discovered or not. The primary objectives of this project were to i) develop a solution that may render a coin cell harmless if it is swallowed and ii) develop a strategy to implement the solution that would be amenable to a high-throughput manufacturing process. To accomplish these objectives, Sandia refined a previously-identified approach toward this aim and found a composite organic/inorganic material that could be applied to a battery that allowed normal battery operation when dry and that would deactivate when wet. This coating formulation is amenable to straightforward deposition onto coin cells using direct-write or extrusion based approaches that benefited from some additional changes in the ink formulation. In summary, Sandia and Duracell, enabled by DOE facilities, developed an effective solution to the rare but horrific damage ingested batteries can do. This solution could have far-reaching effects due to the ubiquity of coin cells, and the potential impact is great for reducing debilitating injury and death caused by ingested coin cells.

Paxton, Walter↗

Experimental investigation and model development of the Skylab ATM secondary nickel-cadmium batteries

The performance of a Ni-Cd battery was evaluated and the cyclic battery controls to be used on the ATM batteries were determined. Cell and battery performance models were developed which to predict the performance of the secondary Ni-Cd batteries on the ATM. Capacity degradation and charge acceptance characteristics were considered. Mathematical models for each of these operating areas were developed based on data from two separate test programs. The capacity degradation model describes the expected usable battery capacity as a function of time, temperature, and depth-of-discharge. The charge acceptance model describes the cell charge acceptance as a function of charge rate, temperature, and state of charge. The models were designed for computer use and to facilitate possible battery modification. They can be used to predict expected performance or to compare real time performance during flight.

Kirsch, W. W.↗

A nickel-cadmium battery reconditioning circuit

The circuit presented is simple and small enough to be included in a typical battery charge/power control assembly, yet provides the advantage of a complete ground-type battery reconditioning discharge. Test results on the circuit when used to recondition two 24 cell, 20 A-h nickel-cadmium batteries are given. These results show that a battery reconditioned with this circuit returns to greater than 90 percent of its original capacity (greater than nameplate capacity) and follows a typical new battery degradation curve even after over 20,000 simulated orbital cycles for a 4 year period. Applications of the circuit are considered along with recommendations relative to its use. Its application in low voltage (22 to 36 Vdc) power systems and in high voltage (100 to 150 Vdc) power systems is discussed. The implications are that the high voltage systems have a greater need for battery reconditioning than their low voltage counterparts, and that using these circuit techniques, the expected life of a battery in low Earth orbit can be up to 5 years.

Lanier, R.↗

Special Test Methods for Batteries

Various methods are described for measuring heat generation in primary and secondary batteries as well as the specific heat of batteries and cell thermal conductance. Problems associated with determining heat generation in large batteries are examined. Special attention is given to monitoring temperature gradients in nickel cadmium cells, the use of auxiliary electrodes for conducting tests on battery charge control, evaluating the linear sweep of current from charge to discharge, and determining zero current voltage. The fast transient behavior of batteries in the microsecond range, and the electrical conductance of nickel sinters in the thickness direction are also considered. Mechanical problems experienced in the vibration of Ni-Cd batteries and tests to simulate cyclic fatigue of the steel table connecting the plates to the comb are considered. Methods of defining the distribution of forces when cells are compressed during battery packaging are also explored.

Gross, S.↗

Results of electric-vehicle propulsion system performance on three lead-acid battery systems

Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries) were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.

Ewashinka, J. G.↗

Nickel hydrogen battery expert system

The Hubble Telescope Battery Testbed at MSFC uses the Nickel Cadmium (NiCd) Battery Expert System (NICBES-2) which supports the evaluation of performance of Hubble Telescope spacecraft batteries and provides alarm diagnosis and action advice. NICBES-2 provides a reasoning system along with a battery domain knowledge base to achieve this battery health management function. An effort is summarized which was used to modify NICBES-2 to accommodate Nickel Hydrogen (NiH2) battery environment now in MSFC testbed. The NICBES-2 is implemented on a Sun Microsystem and is written in SunOS C and Quintus Prolog. The system now operates in a multitasking environment. NICBES-2 spawns three processes: serial port process (SPP); data handler process (DHP); and the expert system process (ESP) in order to process the telemetry data and provide the status and action advice. NICBES-2 performs orbit data gathering, data evaluation, alarm diagnosis and action advice and status and history display functions. The adaptation of NICBES-2 to work with NiH2 battery environment required modification to all of the three component processes.

Shiva, Sajjan G.↗

Hubble Space Telescope nickel-hydrogen flight spare battery test

For several years, MSFC has been engaged in a series of battery tests in support of the Hubble Space Telescope (HST) Program. Now that the HST is in orbit, many of these tests will continue in order to give those responsible for the HST a reasonable prediction on the performance of the flight batteries. These tests will also be a source of needed low earth orbit (LEO) data for nickel hydrogen (Ni-H2) batteries and cells. One of the tests currently in progress at MSFC is a mission simulation test on a 22-cell Ni-H2 battery. This battery is composed of spare cells taken from the lot of cells out of which the Flight Spare Module was assembled. This module is one of two modules launched on the HST. This battery has been on test since Jun. 1989 and has completed nearly 8000 LEO cycles. A series of characterization tests were run prior to the start of the mission simulation and a launch scenario test was run in Feb. and Mar. 1990 to test the behavior of the cells through a simulated launch. The results from these tests as well as the overall performance of the battery as it continues to cycle are reported.

Brewer, Jeffrey C.↗

Nickel cadmium battery operations and performance

The Earth Radiation Budget Satellite (ERBS), Compton Gamma Ray Observatory (CGRO), Upper Atmosphere Research Satellite (UARS), and Extreme Ultraviolet Explorer (EUVE) spacecraft are operated from NASA's Goddard Space Flight Center (GSFC) in Greenbelt, Maryland. On-board power subsystems for each satellite employ NASA Standard 50 Ampere-hour (Ah) nickel-cadmium batteries in a parallel configuration. To date, these batteries have exhibited degradation over periods from several months (anomalous behavior, UARS and CGRO (MPS-1); to little if any, EUVE) to several years (old age, normal behavior, ERBS). Since the onset of degraded performance, each mission's Flight Operations Team (FOT), under the direction of their cognizant GSFC Project Personnel and Space Power Application Branch's Engineers has closely monitored the battery performance and implemented several charge control schemes in an effort to extend battery life. Various software and hardware solutions have been developed to minimize battery overcharge. Each of the four sections of this paper covers a brief overview of each mission's operational battery management and its associated spacecraft battery performance. Also included are new operational procedures developed on-orbit that may be of special interest to future mission definition and development.

Rao, Gopalakrishna↗

Lithium Ion Batteries

Lithium ion batteries, which use a new battery chemistry, are being developed under cooperative agreements between Lockheed Martin, Ultralife Battery, and the NASA Lewis Research Center. The unit cells are made in flat (prismatic) shapes that can be connected in series and parallel to achieve desired voltages and capacities. These batteries will soon be marketed to commercial original-equipment manufacturers and thereafter will be available for military and space use. Current NiCd batteries offer about 35 W-hr/kg compared with 110 W-hr/kg for current lithium ion batteries. Our ultimate target for these batteries is 200 W-hr/kg.

Source record↗

Full-charge indicator for battery chargers

A full-charge indicator for battery chargers, includes a transistor which is in a conductive state as long as charging current to the battery is not less than a level which indicates that the battery did not reach full charge. When the battery reaches full charge, a voltage drop in a resistor in the charging current path is not sufficient to maintain the transistor in a conducting state, and therefore it is switched off. When this occurs an LED is turned on, to indicate a full charge state of the battery. A photocoupler together with a photocoupler transistor are included. When the transistor is off, the photocoupler activates the photocoupler transistor to shunt out a resistor, thereby reducing the charging current to the battery to a float charging current and prevent the battery from being overcharged and damaged.

Cole, Steven W.↗

HST Replacement Battery Initial Performance

The Hubble Space Telescope (HST) original Nickel-Hydrogen (NiH2) batteries were replaced during the Servicing Mission 4 (SM4) after 19 years and one month on orbit.The purpose of this presentation is to highlight the findings from the assessment of the initial sm4 replacement battery performance. The batteries are described, the 0 C capacity is reviewed, descriptions, charts and tables reviewing the State Of Charge (SOC) Performance, the Battery Voltage Performance, the battery impedance, the minimum voltage performance, the thermal performance, the battery current, and the battery system recharge ratio,

Krol, Stan↗

A Comparison of Two Panasonic Lithium-Ion Batteries and Cells for the IBM Thinkpad

The IBM Thinkpad 760XD has been used in the Orbiter and International Space Station since 2000. The Thinkpad is powered by a Panasonic Li-ion battery that has a voltage of 10.8 V and 3.0 Ah capacity. This Thinkpad is now being replaced by the IBM Thinkpad A31P which has a Panasonic Li-ion battery that has a voltage of 10.8 V and 4.0 Ah capacity. Both batteries have protective circuit boards. The Panasonic battery for the Thinkpad 760XD had 12 Panasonic 17500 cells of 0.75 Ah capacity in a 4P3S cOnfiguration. The new Panasonic battery has 6 Panasonic 18650 cells of 2.0 Ah capacity in a 2P3S configuration. The batteries and cells for both models have been evaluated for performance and safety. A comparison of the cells under similar test conditions will be presented. The performance of the cells has been evaluated under different rates of charge and discharge and different temperatures. The cells have been tested under abuse conditions and the safety features in the cells evaluated. The protective circuit board in the battery was also tested under conditions of overcharge, overdischarge, short circuit and unbalanced cell configurations. The results of the studies will be presented in this paper.

Jeevarajan, Judith A.↗

Can Cell to Cell Thermal Runaway Propagation be Prevented in a Li-ion Battery Module?

Increasing cell spacing decreased adjacent cell damage center dotElectrically connected adjacent cells drained more than physically adjacent cells center dotRadiant barrier prevents propagation when fully installed between BP cells center dotBP cells vent rapidly and expel contents at 100% SOC -Slower vent with flame/smoke at 50% -Thermal runaway event typically occurs at 160 degC center dotLG cells vent but do not expel contents -Thermal runaway event typically occurs at 200 degC center dotSKC LFP modules did not propagate; fuses on negative terminal of cell may provide a benefit in reducing cell to cell damage propagation. New requirement in NASA-Battery Safety Requirements document: JSC 20793 Rev C 5.1.5.1 Requirements - Thermal Runaway Propagation a. For battery designs greater than a 80-Wh energy employing high specific energy cells (greater than 80 watt-hours/kg, for example, lithium-ion chemistries) with catastrophic failure modes, the battery shall be evaluated to ascertain the severity of a worst-case single-cell thermal runaway event and the propensity of the design to demonstrate cell-to-cell propagation in the intended application and environment. NASA has traditionally addressed the threat of thermal runaway incidents in its battery deployments through comprehensive prevention protocols. This prevention-centered approach has included extensive screening for manufacturing defects, as well as robust battery management controls that prevent abuse-induced runaway even in the face of multiple system failures. This focused strategy has made the likelihood of occurrence of such an event highly improbable. b. The evaluation shall include all necessary analysis and test to quantify the severity (consequence) of the event in the intended application and environment as well as to identify design modifications to the battery or the system that could appreciably reduce that severity. In addition to prevention protocols, programs developing battery designs with catastrophic failure modes should take the steps necessary to assess the severity of a possible thermal runaway event. Programs should assess whether there are reasonable design changes that could appreciably affect the severity of the outcome. Evaluation should include environmental effects to surrounding hardware (i.e., temperature, pressure, shock), contamination effects due to any expelled contaminates, and venting propulsive effects when venting overboard.

Jeevarajan, Judith↗

Summary of 2017 NASA Workshop on Assessment of Advanced Battery Technologies for Aerospace Applications

A workshop on assessment of battery technologies for future aerospace applications was held in Cleveland, OH on August 16-17. The focus of the workshop, hosted by NASA GRC, was to assess (1) the battery needs for future aerospace missions, (2) the state of battery technology and projected technology advances, and (3) the need for additional investments for future aerospace missions. The workshop had 109 attendees that included internationally recognized technology leaders from academia and national laboratories, high level executives from government and industry, small businesses, and startup companies. A significant portion of the workshop was focused on batteries for electrified aircraft. The presentation will summarize the finding on the state of battery technologies for electrified aircraft and will include assessment of current state of battery technology, gaps in battery technology for application in electrified aircraft, and recommended technology development options for meeting near-term and long-term needs of electrified aircraft.

Misra, Ajay↗

A Prognostics Framework for Battery Health Monitoring Integrated with Thermal Modeling

Urban Air Mobility (UAM) promises to revolutionize transportation in major cities, offering passenger travel, cargo delivery, and emergency medical services through a network of electric vertical takeoff and landing (eVTOL) aircraft. However, the limited range of current eVTOLs, due to the low specific energy of lithium-ion batteries along with a possibility of thermal runaway conditions poses significant safety concerns, leading to potentially compromising operational safety. To address this critical challenge, researchers are actively evaluating the impact of flight and environmental conditions on onboard lithium-ion battery health. This involves carefully assessing the performance of battery packs under laboratory and operational conditions for developing models to estimate future health using prognostics framework. This study examines the effectiveness of evaluating battery degradation leading to catastrophic failures under varying operational conditions in laboratory. These are captured using physics based models of underlying phenomenons and integrated into the prognostics framework. A fully charged battery undergoes controlled discharge cycles at varying C-rates based on the simulated power draw profile, with current and voltage, temperature data recorded throughout the experiment. The observed data provides valuable insights into how different operating conditions and mission profiles affect battery performance. This information is crucial for developing strategies to optimize battery systems, enhance range, and ultimately ensure the safe and reliable operation of UAM vehicles.

Thermal Modeling↗

A Prognostics Framework for Battery Health Monitoring Integrated with Thermal Modeling

Urban Air Mobility (UAM) promises to revolutionize transportation in major cities, offering passenger travel, cargo delivery, and emergency medical services through a network of electric vertical takeoff and landing (eVTOL) aircraft. However, the limited range of current eVTOLs, due to the low specific energy of lithium-ion batteries along with a possibility of thermal runaway conditions poses significant safety concerns, leading to potentially compromising operational safety. To address this critical challenge, researchers are actively evaluating the impact of flight and environmental conditions on onboard lithium-ion battery health. This involves carefully assessing the performance of battery packs under laboratory and operational conditions for developing models to estimate future health using prognostics framework. This study examines the effectiveness of evaluating battery degradation leading to catastrophic failures under varying operational conditions in laboratory. These are captured using physics based models of underlying phenomenons and integrated into the prognostics framework. A fully charged battery undergoes controlled discharge cycles at varying C-rates based on the simulated power draw profile, with current and voltage, temperature data recorded throughout the experiment. The observed data provides valuable insights into how different operating conditions and mission profiles affect battery performance. This information is crucial for developing strategies to optimize battery systems, enhance range, and ultimately ensure the safe and reliable operation of UAM vehicles.

Thermal Modeling↗

Progress of Aluminum/Air Battery Development for SUSAN Electrofan Project

Safe and high-performance battery technologies are demanded by the Subsonic Single Aft eNgine (SUSAN) Electrofan concept design project under National Aeronautics and Space Administration (NASA) electrified aircraft development program. Aluminum (Al)-air battery with very high theoretical specific energy density, is considered as promising battery chemistry which has the potential to meet the targeted specific energy goal of primary battery energy technology for the SUSAN project. In addition to having the exceptional electrochemical properties, aluminum is light weight, rich abundance, low cost, environmentally friendly, and has a good electrical conductivity and recyclability, which is among the key characteristics of SUSAN project on battery energy needs. A non-flammable aqueous electrolyte is used to prevent the fire and thermal runaway hazard for the safety of this battery chemistry. However, there are challenges for Al-air battery in practical application, mainly due to self-corrosion of Al and slow kinetics of oxygen reduction in air-cathode to impact the high-rate performance. Progress on addressing these challenges was made and some of the results were reported in our previous paper. In this paper, the focus is on the investigation of various factors, including electrolyte concentrations, temperature, and air-cathode loadings on ionic transport properties and discharge performance at different current densities. The results are discussed, and the progress is reported.

James J Wu↗