Search NASA⌕ Search

Engineering topics

Thermal systems

Find NASA NTRS and DOE OSTI research on heat transfer and thermal systems. Search heat pipes, cooling and thermal management in report titles and abstracts.

At least 541 records · Page 30

Effects of thermal loading on foil and sheet composites with constituents of differing thermal expansivities.

A study was made to estimate the magnitudes of elastic stresses and elastic-plastic stresses and strains in sheet or foil laminar composites. Using a model tungsten/80Ni + 20Cr laminar composite and assuming cooling or heating through a temperature range of 80-2000 deg F (26.5-1093.5 deg C), calculated elastic stresses exceeded published or estimated strengths of the constituents. Elastic-plastic stress-strain solutions resulted in lower estimated stress levels but with the concomitant occurrence of sufficiently large strain ranges to suggest possible thermal fatigue problems. Limited experimental studies using tungsten/80Ni + 20Cr foil and sheet laminar composites, slowly cycled between 80 and 2000 deg F (26.5-1093.5 deg C) or rapidly cycled between 80 and 1600 deg F (26.5-871 deg C) produced varying degrees of observable structural damage in from 1 to 11 cycles depending upon temperature transition rate and laminae thickness; these particular results might not occur with other combinations of materials.

Hoffman, C. A.↗

Effects of thermal loading on fiber-reinforced composites with constituents of differing thermal expansivities.

Estimates of the magnitudes of elastic stresses and elastoplastic stresses and strains were made for tungsten fiber-reinforced 80Ni + 20Cr matrix composites. Heating or cooling between 80 and 2000 F was assumed. The calculated elastic stresses exceeded representative or estimated strengths of constituents. For composites with less than 0.65 volume fraction of fiber, plastic flow was considered possible, and elastoplastic solutions indicated that stresses would be reduced but with the concomitant occurrence of sufficiently large strain ranges, particularly in the matrix, to pose a possible thermal fatigue problem. Limited experimental studies on tungsten fiber-copper matrix composites heated and cooled a number of times between 80 and 1600 F in a conventional furnace and then heated from 80 to 1652 F in a hot-stage microscope resulted in matrix microfracture for a 70 volume fraction fiber composite and substantial matrix strain for a 40 volue fraction fiber composite.

Hoffman, C. A.↗

Prolonging thermal barrier coated specimen life by thermal cycle management

Measurements were made of the rate of increase in temperature of a ZrO2-8Y2O3 thermal barrier coated (TBC) specimen for various values of fuel/air (F/A) ratios when the specimen is exposed to a 0.3 Mach burner flame. For rod specimens in a carousel, the heating rates increased with (F/A) ratio and were higher at the inward facing surface for a given (F/A). Plate specimens were more sensitive to burner variations. Calculated results are given for the radial stress in the coated rod specimens for variations in (F/A) ratios from 0.04 to 0.065. Over this range, the radial stress varies from 4.3 to 5.3 MPa. The results indicate that controlling the heating rate of a TBC by controlling the (F/A) ratio offers a potential method to prolong TBC cyclic life; uncontrolled (F/A) ratios will produce scatter in experimental results. Geometric arrangement can have an equivalent effect, but is usually fixed by design.

Hendricks, R. C.↗

Thermal Pollution Math Model. Volume 1. Thermal Pollution Model Package Verification and Transfer

Two three dimensional, time dependent models, one free surface, the other rigid lid, were verified at Anclote Anchorage and Lake Keowee respectively. The first site is a coastal site in northern Florida; the other is a man-made lake in South Carolina. These models describe the dispersion of heated discharges from power plants under the action of ambient conditions. A one dimensional, horizontally-averaged model was also developed and verified at Lake Keowee. The data base consisted of archival in situ measurements and data collected during field missions. The field missions were conducted during winter and summer conditions at each site. Each mission consisted of four infrared scanner flights with supporting ground truth and in situ measurements. At Anclote, special care was taken to characterize the complete tidal cycle. The three dimensional model results compared with IR data for thermal plumes on an average within 1 C root mean square difference. The one dimensional model performed satisfactorily in simulating the 1971-1979 period.

Lee, S. S.↗

Thermal barrier coatings for thermal insulation and corrosion resistance in industrial gas turbine engines

Four thermal barrier coatings were subjected to a 500-hour gas turbine engine test. The coatings were two yttria stabilized zirconias, calcium ortho silicate and calcium meta titanate. The calcium silicate coating exhibited significant spalling. Yttria stabilized zirconia and calcium titanate coatings showed little degradation except in blade leading edge areas. Post-test examination showed variations in the coating due to manual application techniques. Improved process control is required if engineering quality coatings are to be developed. The results indicate that some leading edge loss of the coating can be expected near the tip.

Vogan, J. W.↗

Thermal expansion mismatch and plasticity in thermal barrier coating

The basic objective of this investigation is the quantitative determination of stress states in a model thermal barrier coating (TBC) as it cools in the air to 600 C from an assumed stress-free state at 700 C. This model is intended to represent a thin plasma-sprayed zirconia-yttria ceramic layer with a nickel chromium-aluminum-yttrium bond coat on a cylindrical substrate made of nickel-based superalloys typically found in gas turbines.

Chang, George C.↗

Viscosity and thermal fields associated with strongly chaotic non-Newtonian thermal convection

The thermomechanical structure is investigated in strongly chaotic non-Newtonian thermal convection for both base-heated and internally-heated systems. Temperature can build up in stagnant regions and a non-Newtonian mantle can tolerate less internal heating. Viscosity fields of the strongly chaotic regime show a granular structure. The horizontal spectra of viscosity fluctuations obey a power-law and yield a fractal dimension of 1.6 to 1.8 for the isoviscosity lines, providing evidence for 2D turbulence. Long-wavelength viscosity variations are smoothed out by the turbulent non-Newtonian flows.

Malevsky, A. V.↗

On the thermal stability of a radiating plasma subject to nonlocal thermal conduction. I - Linear analysis

We study the linear stability of an optically thin uniform radiating plasma subject to nonlocal heat transport. We derive the dispersion relation appropriate to this problem, and the marginal wavenumbers for instability. Our analysis indicates that nonlocal heat transport acts to reduce the stabilizing influence of thermal conduction, and that there are critical values for the electron mean free path such that the plasma is always unstable. Our results may be applied to a number of astrophysical plasmas, one such example being the halos of clusters of galaxies.

Chun, E.↗

Thermal analysis of a functionally graded material subject to a thermal gradient using the boundary element method

The boundary element method is utilized in this study to conduct thermal analysis of functionally graded composites, materials in which the internal microstructure or properties are explicitly tailored in order to obtain an optimal response, on the micromechanical (constituent) scale. A unique feature of the boundary element formulations used here is the use of circular shape functions to convert the two-dimensional integrations of the composite fibers to one dimensional integrations. Using the computer code BEST-CMS, the through the thickness temperature profiles are computed for a representative material with varying numbers of fibers and fiber spacing in the thickness direction. The computed temperature profiles are compared to those obtained using an alternate analytical theory which explicitly couples the heterogeneous microstructure to the global analysis. The boundary element results compared favorably to the analytical calculations, with discrepancies that are explainable based on the boundary element formulation. The results serve both to demonstrate the ability of the boundary element method to analyze these types of materials, and to verify the accuracy of the analytical theory.

Goldberg, Robert K.↗

Evaluation of Thermal Control Coatings for Flexible Ceramic Thermal Protection Systems

This report summarizes the evaluation and testing of high emissivity protective coatings applied to flexible insulations for the Reusable Launch Vehicle technology program. Ceramic coatings were evaluated for their thermal properties, durability, and potential for reuse. One of the major goals was to determine the mechanism by which these coated blanket surfaces become brittle and try to modify the coatings to reduce or eliminate embrittlement. Coatings were prepared from colloidal silica with a small percentage of either SiC or SiB6 as the emissivity agent. These coatings are referred to as gray C-9 and protective ceramic coating (PCC), respectively. The colloidal solutions were either brushed or sprayed onto advanced flexible reusable surface insulation blankets. The blankets were instrumented with thermocouples and exposed to reentry heating conditions in the Ames Aeroheating Arc Jet Facility. Post-test samples were then characterized through impact testing, emissivity measurements, chemical analysis, and observation of changes in surface morphology. The results show that both coatings performed well in arc jet tests with backface temperatures slightly lower for the PCC coating than with gray C-9. Impact testing showed that the least extensive surface destruction was experienced on blankets with lower areal density coatings.

Kourtides, Demetrius↗

Thermal Control Utilizing an Thermal Control Utilizing an Two-Phase Loop with High Heat Flux Source

The electric field applied in dielectric fluids causes an imbalance in the dissociation-recombination reaction generated free space charges. The generated charges are redistributed by the applied electric field resulting in the heterocharge layers in the Vicinity of the electrodes. Proper design of the electrodes generates net axial flow motion pumping the fluid. The electrohydrodynamic (EHD) conduction pump is a new device that pumps dielectric fluids utilizing heterocharge layers formed by imposition of electrostatic fields. This paper evaluates the experimental performance of a two-phase breadboard thermal control loop consisting of an EHD conduction pump, condenser, pre-heater, high heat flux evaporator (HE), transport lines, and reservoir (accumulator). The generated pressure head and the maximum applicable heat flux are experimentally determined at various applied voltages and sink temperatures. Recovery from dryout condition by increasing the applied voltage to the pump is also demonstrated.

Jeong, Seong-Il↗