Super-hydrophobic, thermally insulating, thermal-shocks resistant well cement composites for completion of geothermal wells at hydrothermal temperatures of up to 300° C

A well cement composite and a method for making a well cement composite includes a mixture of calcium aluminate cement (CAC) and fly ash cenospheres (CS) in a weight ratio of from 30:70 to 80:20 CAC to CS; sodium metasilicate (SMS) in an amount of from 1 to 10% of the total weight of the mixture of CAC and CS; polymethylhydrosiloxane (PMHS) in an amount of from 0.5 to 6.0% of the total weight of the mixture of CAC and CS; and water in a weight ratio of from 0.5:1.0 to 1.2:1.0 of water to CAC and CS.

Pyatina, Tatiana↗

An Investigation of Thermal Properties of 2D Materials [Dissertation]

Studying the thermal conductivity of 2D materials is important due to the applications of 2D materials in fields such as thermal management, thermoelectricity, renewable energy, and sensors. As such, measurements of the thermal conductivity of these 2D materials become important to measure. Thermal conductivity is often difficult to measure for 2D materials due to their atomically thin nature and many experimental methods for doing so requiring contact with the sample, which can alter the thermal properties. A non-contact method for calculating the thermal conductivity of 2D materials supported on substrates in order to model the thermal conductivity of 2D materials for devices, is proposed and experimentally performed in this dissertation. The optothermal Raman technique is a useful non-contact diagnostic technique useful in determining the thermal conductivity of 2D materials. The optothermal Raman typically does not account for heat losses due to convection or radiation or substrate resistance, which are shown to be important factors to consider when developing an optothermal Raman model. Additionally, the calculation of the interfacial thermal conductance between the bottom surface of the sample and the top surface of the substrate, plays an important role in determining the final value of the thermal conductivity of a supported sample, and will yield differing results based on whether or not the conductance is calculated using an approach such as the Diffuse Mismatch Model (DMM) or calculated directly by varying the laser heating profile (usually done by changing the laser objective). This is shown to be the case for both graphene on Ni, graphene on Cu, and SnSe 2 on Cu. In addition to experimentally calculating the thermal conductivity of a 2D material with the optothermal Raman technique, the thermal conductivity of 2D materials can also be calculated using computational methods. The three-phonon method is a method which can be used to simulate phonon scattering processes and determine the thermal conductivity of semiconductors, wherein phonon scattering is the dominant mechanism which determines the thermal conductivity. The three-phonon method uses relaxation times for phonon scattering with other phonons, electrons, and other material system elements, such as isotopes or material defects, in order to create a single-mode relaxation time approximation (SMRTA), which is used to calculate the final value of the thermal conductivity. An important consideration when determining the thermal conductivity of a 2D material using this method is the device geometry, which is reflected in this work as the phonon-boundary scattering relaxation time. This inclusion is important along with the inclusion of phonon-electron scattering in accurately determining the thermal conductivity of a 2D material. In both the optothermal Raman experiments and the three-phonon method computations, strain is shown to have a demonstrable effect on the thermal conductivity of 2D materials. When a 1.1% strain was applied to the mechanical properties of SnSe, the three-phonon processes yielded a lower thermal conductivity than the no-strain case. For the optothermal Raman experiments, the strain induced in the Cu substrate and transferred to a single-layer graphene (SLG) sample yields a trend where the thermal conductivity of the SLG decreases with respect to strain applied. In the case where the interfacial thermal conductance was calculated directly, the conductance increased with respect to strain applied. This presents strain as a reliable and viable method for tuning the thermal properties of 2D materials for device applications.

36 MATERIALS SCIENCE↗

Thermally Conductive Backsheets (TCB) for Reduced Operating Temperatures

The performance of photovoltaic (PV) modules is primarily influenced by the plane of array (POA) irradiance and their operating temperature. The lower the module operating temperature, the higher is its performance. Increasing a module’s operating temperature reduces its power output due to an increase in the semiconductor’s intrinsic carrier density, leading to a reduction in the open-circuit voltage and, subsequently, reducing the maximum power point voltage. Reducing the operating temperature lowers the levelized cost of energy (LCOE) via increased energy production (i.e., more kilowatt hour over the life of the asset) and increased service lifetime (years in the field). The module operating temperature is dictated by the weather parameters and the thermal properties of module construction materials. The primary weather parameters influencing the PV module temperature are: the ambient temperature (directly related), irradiance (directly related), and wind speed (inversely related). The primary thermal properties of module construction materials influencing the PV module temperature are: the optical transmissivity and thermal conductivity of superstrate, the thermal conductivity of substrate, the thermal conductivity of encapsulant and the efficiency of the encapsulated solar cells. The primary goal of this study is to reduce the operating temperature of PV modules using thermally conductive backsheet (TCB) substrates developed by the industry. The temperature of PV modules installed in a large multi-MW plant can also be influenced by their physical locations in the plants due to the influence of wind direction. A thermal mapping of PV plants has also been investigated and presented in this study. The most commonly used PV backsheet material has been polyvinyl fluoride (DuPont trade name “Tedlar”)-based backsheet, which typically has three layers: Tedlar–polyethylene terephthalate (PET)–Tedlar (TPT). The primary goal of this project is to reduce the module operating temperature below the benchmark TPT backsheet temperature using newly developed TCBs by the industry. The overall approach of this project involves six focus areas: i) select and procure one TPT and thirteen promising TCBs available in the industry; ii) construct a large number of 1-cell and 9-cell modules using benchmark TPT and selected TCBs [all other construction materials are fixed and they are: glass superstrate, EVA encapsulant, mono-Si cell and junction box]; iii) to identify best performing TCBs, monitor the long-term field operating temperatures of the constructed modules which are installed in three climatic conditions (hot-low wind [Mesa, AZ], hot-high wind [Maricopa County, AZ] and temperate [Cumberland County, NC]; iv) to identify the most durable TCB, perform extended accelerated reliability testing of modules constructed with best three TCBs and benchmark TPT; v) to predict module temperature, develop physical and empirical thermal models with and without thermal properties of all construction materials in the modules, respectively; and vi) to determine the influence of wind speed and direction on the module operating temperature in a plant, and perform thermal mapping of PV modules in two large PV plants [Maricopa County, AZ and Cumberland County, NC]. The key achievements of this project are listed below: Backsheet selection: 14 backsheets were procured after an extensive literature and industry search. Finally, based on the thermal and other selection criteria, 1 TPT and 4 thermally conductive backsheets were selected for this project. Fabrication of mini modules: 50 one-cell modules were fabricated in year 1 for thermal performance evaluation. The module design was changed to nine-cell module at start of year 2 to mimic commercial design. 20 nine-cell modules were fabricated in year 2 for thermal performance evaluation. 28 four-cell modules were fabricated in year 3 for accelerated stress-testing. Thermal conductivity of backsheets: Year 1 TCBs showed at least 8% higher thermal conductivities than TPT. Year 2 and 3 TCBs showed at least 20% higher thermal conductivities than TPT. Installation of mini PV modules at three sites: 6 one-cell modules and 8 nine-cell modules were installed at AZ-1 site [Mesa, AZ]. 12 one-cell modules and 6 nine-cell modules were installed at each of two powerplants (AZ-2 [Maricopa County, AZ] and NC sites). Nominal operating cell temperatures (NOCT) of mini PV modules: NOCT of TCBs were observed to be lower than TPT with differences as high as 2°C. Comparison of thermal performance: The median operating temperature of one-cell modules was found to be reduced by 2°C by using TCB_A modules compared to TPT modules on several days in a month for few months in a year. The median temperature improvement of 4oC was achieved at several instances on a few days, but not all days, in a year using multiple TCBs compared to TPT. The final project milestone of achieving median temperature improvement of 5oC was achieved at several instances on a few days, but not all days, in a year using TCB_A compared to TPT. Empirical thermal model (without the need of construction material properties): Empirical thermal model for one-cell module was developed based on the input data of irradiance, wind speed and ambient temperatures. The primary input data differentiator for temperature differences between TPT and TCBs appears to be the irradiance level (solar gain). Accelerated durability testing: 20 four-cell modules using 4 backsheets (1 TPT and 3 TCBs) were exposed to Damp Heat 1000 hours (8 modules), UV/Thermal cycling (50 cycles)/Humidity freeze (10 cycles) test sequence (8 modules) and UV Weathering for qualification (8 modules). All the modules with four selected backsheets passed the stress tests per the retest guidelines of IEC 61215 standard for the backsheet change. Simplified comparative LCOE analysis: Using backsheet-specific power degradation levels in the accelerated tests (for TCB_A and TPT only), efficiency, service lifetime and assuming same cost for all backsheets, the LCOE of modules using TCB_A is determined to be lower than TPT. Due to lower operating temperature of TCB_A-based modules compared to TPT-based modules, the operating efficiency and service life of TCB_A-based modules are calculated to be higher than TPT-based modules. Temperature mapping of PV power plants: A distinct temperature difference (as high as 4°C) has been observed between the modules located in various parts of a single PV plant.

14 SOLAR ENERGY↗

Evaluating Heat Extraction Performance of Closed-Loop Geothermal Systems with Thermally Conductive Enhancements in Conduction-Only Reservoirs: Preprint

We investigated the impact of disc-shaped and linear thermal enhancements on performance of closed-loop geothermal systems using steady-state and transient COMSOL numerical simulations. Thermal enhancements refer to thermally conductive material introduced in the rocks surrounding a wellbore to compensate for the relatively low rock thermal conductivity and increase heat extraction. Materials proposed include composite cements with thermally conductive additives such as metals or graphite to obtain overall cement thermal conductivities of 10 to 100x the rock thermal conductivity. Our simulation approach was modeling a subsegment (e.g., 100 m long) of a wellbore with idealized (e.g., perfect disc-shaped) thermal enhancements, and we report results as relative increase in heat extraction with respect to systems without thermal enhancements. We did not evaluate technical feasibility or cost of installing thermal enhancements. Simulations indicate that for 5-mm thick disc-shaped thermal enhancements with 5-m radius, repeated every 1 m along the wellbore and with thermal conductivity of 100x the rock thermal conductivity, the thermal output increases roughly 20% with respect to a closed-loop system without thermal enhancements. For fishbone structure thermal enhancements, we estimate a roughly 7% increase in thermal output for 5-m long radially outward pipes with half the radius of the main wellbore, repeated every 2.5 m, with thermal conductivity of 100x the rock thermal conductivity.

advanced geothermal systems↗

Comparing Growth Rates of Simulated Moist and Dry Convective Thermals

The spreading rates of convective thermals are linked to their net entrainment, and previous literature has suggested differences in spreading rates between moist and dry thermals. Here, growth rates of idealized numerically simulated axisymmetric dry and moist convective thermals are directly compared. In an environment with dry-neutral stratification, the increase of thermal radius with height dR / dz is a larger by a factor of 1.7 for dry thermals relative to moist thermals. The fractional change in thermal volume ε is also greater for dry thermals within a distance of ~4 radii from the initial thermal height. Values of dR / dz are nearly constant with height for both moist and dry thermals consistent with classical theory based on dimensional analysis. The simulations are also consistent with theory relating impulse, circulation, and spreading rate for dry thermals proposed in previous papers and extended here to moist thermals, predicting they will spread less than dry thermals. Tests adding heating to dry thermals, either spread uniformly across the thermal volume or concentrated in the inner core, indicate that dR / dz and ε are smaller for moist thermals because latent heating is confined mostly to their cores. Additional axisymmetric moist simulations using modified lapse rates and large-eddy simulations support this analysis. Overall, these results indicate that slow spreading rates are a fundamental feature of moist thermals caused by latent heating that alters the spatial distribution of buoyancy within them relative to dry thermals.

54 ENVIRONMENTAL SCIENCES↗

Entropy generation method to quantify thermal comfort

The present paper presents a thermodynamic approach to assess the quality of human-thermal environment interaction and quantify thermal comfort. The approach involves development of entropy generation term by applying second law of thermodynamics to the combined human-environment system. The entropy generation term combines both human thermal physiological responses and thermal environmental variables to provide an objective measure of thermal comfort. The original concepts and definitions form the basis for establishing the mathematical relationship between thermal comfort and entropy generation term. As a result of logic and deterministic approach, an Objective Thermal Comfort Index (OTCI) is defined and established as a function of entropy generation. In order to verify the entropy-based thermal comfort model, human thermal physiological responses due to changes in ambient conditions are simulated using a well established and validated human thermal model developed at the Institute of Environmental Research of Kansas State University (KSU). The finite element based KSU human thermal computer model is being utilized as a "Computational Environmental Chamber" to conduct series of simulations to examine the human thermal responses to different environmental conditions. The output from the simulation, which include human thermal responses and input data consisting of environmental conditions are fed into the thermal comfort model. Continuous monitoring of thermal comfort in comfortable and extreme environmental conditions is demonstrated. The Objective Thermal Comfort values obtained from the entropy-based model are validated against regression based Predicted Mean Vote (PMV) values. Using the corresponding air temperatures and vapor pressures that were used in the computer simulation in the regression equation generates the PMV values. The preliminary results indicate that the OTCI and PMV values correlate well under ideal conditions. However, an experimental study is needed in the future to fully establish the validity of the OTCI formula and the model. One of the practical applications of this index is that could it be integrated in thermal control systems to develop human-centered environmental control systems for potential use in aircraft, mass transit vehicles, intelligent building systems, and space vehicles.

Models, Biological↗

NASA Passive Thermal Control Engineering Guidebook

The NASA Passive Thermal Control Engineering Guidebook provides recommendations, including best practices and lessons learned, related to the passive thermal control engineering discipline. Topics include analysis (including documentation and review), thermal hardware (design/selection, vendors, and integration), testing, and flight operations. The passive thermal discipline includes thermal control and thermal protection systems. The passive thermal control discipline, which is addressed in this Guidebook, is broad and covers internal and external systems, component passive thermal analysis, vehicle on-orbit attitude timeline analysis, integrated thermal analysis, various thermal control apparatus (heaters and controls, coatings, blankets and insulations, isolators, geometric design for view factors, materials emissivity/absorptivity properties), passive cooling of avionics, purge, vent, and drain for vehicle cavities and compartments, thermal model development and correlation, thermal cycle and thermal-vacuum testing. Topics related to thermal protection systems (TPS) are not within the scope of this document. The Guidebook provides a consolidated reference for early career as well as experienced engineers embarking on a new task. Leveraging the experience of the group minimizes the learning curve that exists at the start of new projects, reduces the risk of repeating mistakes, and improves the organization’s ability to deliver high-quality products efficiently. The intent of this document is to provide guidance based on collective experience, and is not intended impose constraints on project work. Best practices can vary substantially and it is important to apply judgment wisely based on careful consideration of the specific design and requirements. Implementation of the methods described will vary from project to project and should be applied in conjunction with the judgment of the thermal engineers performing and reviewing the work. The recommendations in this document are not intended to replace program, project, branch, Center, or NASA requirements and/or policies.

thermal↗

NASA Passive Thermal Control Engineering Guidebook

The NASA Passive Thermal Control Engineering Guidebook provides recommendations, including best practices and lessons learned, related to the passive thermal control engineering discipline. Topics include analysis (including documentation and review), thermal hardware (design/selection, vendors, and integration), testing, and flight operations. The passive thermal discipline includes thermal control and thermal protection systems. The passive thermal control discipline, which is addressed in this Guidebook, is broad and covers internal and external systems, component passive thermal analysis, vehicle on-orbit attitude timeline analysis, integrated thermal analysis, various thermal control apparatus (heaters and controls, coatings, blankets and insulations, isolators, geometric design for view factors, materials emissivity/absorptivity properties), passive cooling of avionics, purge, vent, and drain for vehicle cavities and compartments, thermal model development and correlation, thermal cycle and thermal-vacuum testing. Topics related to thermal protection systems (TPS) are not within the scope of this document. The Guidebook provides a consolidated reference for early career as well as experienced engineers embarking on a new task. Leveraging the experience of the group minimizes the learning curve that exists at the start of new projects, reduces the risk of repeating mistakes, and improves the organization’s ability to deliver high-quality products efficiently. The intent of this document is to provide guidance based on collective experience, and is not intended impose constraints on project work. Best practices can vary substantially and it is important to apply judgment wisely based on careful consideration of the specific design and requirements. Implementation of the methods described will vary from project to project and should be applied in conjunction with the judgment of the thermal engineers performing and reviewing the work. The recommendations in this document are not intended to replace program, project, branch, Center, or NASA requirements and/or policies.

thermal↗

Understanding Thermal Transport in Polymer –Silver Nanowire Composites

Understanding thermal transport across filler-polymer interfaces and filler-filler contacts within polymer composites is of great importance for better thermal design of the composites that are widely used in high-performance heat exchangers, energy storage devices, and flexible electronics. Over the past several decades, considerable progress has been made in improving the thermal conductivity of polymer composites, but several key questions concerning the influence of interfacial thermal resistance, or Kapitza resistance, still remain. Firstly, the thermal properties of these composites are highly dependent on thermal transport through the filler network and its contacts. For metallic nanofillers, the thermal conductivity is often estimated using the Wiedemann-Franz law based on electrical conductivity; however, it remains a question whether the Wiedemann-Franz law still holds at nanoscale contacts. Through investigation of silver nanowires of varying sizes, we were able to demonstrate that the Lorenz number for silver nanowire increases with decreasing nanowire diameter. Examination of the corresponding electrical and thermal conductivities indicate that these changes are due to that the relative contribution of phonons becomes more significant as a result of elastic stiffening. Furthermore, we show that for silver nanowires, the contact thermal resistance is ~8 times lower than that of multi-walled carbon nanotube (MWCNT) of similar diameters. Additionally, through systematic studies of electrospun polymer-silver nanowire composite nanofibers, we investigated the impact of interface morphology on the thermal conductivity enhancement of the composite system and probed the value of the Kapitza resistance for individual polymer-filler interfaces. For polymer nanofibers containing continuous, single silver nanowires, the thermal conductivity increases linearly with increasing volume fraction of silver, which is consistent with the prediction of percolation theory for samples above the percolation limit. By comparing this linear trend to the measured thermal conductivities of composite nanofibers with more complex structures, we were able to determine the resistance associated with any additional polymer-filler boundaries. In doing so we find that the thermal boundary resistance for polyvinylpyrrolidone (PVP)–silver interfaces is significantly lower than that of comparable polymer-MWCNT composite systems.Together our studies provide new insights into thermal transport in polymer nanocomposites and should help facilitate the design of high performance polymeric thermal interface material.

Thermal transport↗

Entrainment, Detrainment, and Dilution of Dry and Moist Atmospheric Thermals

Here this study examines the entrainment, detrainment, and dilution of dry and moist (cloud) atmospheric thermals in large-eddy simulations. In a neutrally stable environment (with respect to dry dynamics), moist thermals have an increase in radius R with thermal height z t (α ≡ dR/dz t ) about 4 times smaller compared to dry thermals when density stratification is considered and ~2.4 times smaller without density stratification (i.e., applying the Boussinesq approximation). An analytic expression relating α to several dimensionless parameters is derived from the thermal impulse–circulation relation to clarify the factors impacting α. This expression shows that the difference in buoyancy structure between moist and dry thermals, with buoyancy concentrated in the central cores of moist thermals owing to latent heating, explains their smaller spreading rates. Individual contributions of entrainment and detrainment are analyzed using a direct parcel-based approach in the simulations. Moist thermals have similar fractional detrainment but much smaller fractional entrainment rates compared to dry thermals, consistent with the differences in α. Despite having smaller α, moist thermals are similarly dilute (quantified by a passive tracer) as dry thermals because of their greater mixing efficiency with the environment. Thus, moist thermals are substantially dilute but expand much less in size/volume as they rise compared to dry thermals. The α values for moist thermals in (dry) neutral and statically stable environments are similar, but fractional entrainment and especially detrainment rates are greater in the stable environment. Large detrainment rates are associated with a breakdown of the broader thermal vortex ring structure, especially with low environmental relative humidity, attributed in part to evaporation and buoyancy reversal.

54 ENVIRONMENTAL SCIENCES↗

Understanding Thermal Transport in Polymer - Silver Nanowire Composites

Understanding thermal transport across filler-polymer interfaces and filler-filler contacts within polymer composites is of great importance for better thermal design of the composites that are widely used in high-performance heat exchangers, energy storage devices, and flexible electronics. Over the past several decades, considerable progress has been made in improving the thermal conductivity of polymer composites, but several key questions concerning the influence of interfacial thermal resistance, or Kapitza resistance, still remain. Firstly, the thermal properties of these composites are highly dependent on thermal transport through the filler network and its contacts. For metallic nanofillers, the thermal conductivity is often estimated using the Wiedemann-Franz law based on electrical conductivity; however, it remains a question whether the Wiedemann-Franz law still holds at nanoscale contacts. Through investigation of silver nanowires of varying sizes, we were able to demonstrate that the Lorenz number for silver nanowire increases with decreasing nanowire diameter. Examination of the corresponding electrical and thermal conductivities indicate that these changes are due to that the relative contribution of phonons becomes more significant as a result of elastic stiffening. Furthermore, we show that for silver nanowires, the contact thermal resistance is ~8 times lower than that of multi-walled carbon nanotube (MWCNT) of similar diameters. Additionally, through systematic studies of electrospun polymer-silver nanowire composite nanofibers, we investigated the impact of interface morphology on the thermal conductivity enhancement of the composite system and probed the value of the Kapitza resistance for individual polymer-filler interfaces. For polymer nanofibers containing continuous, single silver nanowires, the thermal conductivity increases linearly with increasing volume fraction of silver, which is consistent with the prediction of percolation theory for samples above the percolation limit. By comparing this linear trend to the measured thermal conductivities of composite nanofibers with more complex structures, we were able to determine the resistance associated with any additional polymer-filler boundaries. In doing so we find that the thermal boundary resistance for polyvinylpyrrolidone (PVP)–silver interfaces is significantly lower than that of comparable polymer-MWCNT composite systems. Together our studies provide new insights into thermal transport in polymer nanocomposites and should help facilitate the design of high performance polymeric thermal interface material.