Search NASA⌕ Search

Engineering topics

Thermal systems

Find NASA NTRS and DOE OSTI research on heat transfer and thermal systems. Search heat pipes, cooling and thermal management in report titles and abstracts.

At least 1,765 records · Page 98

Thermal Behaviour of Unusual Local-Scale Surface Features on Vesta

On Vesta, the region of the infrared spectrum beyond approximately 3.5 micrometers is dominated by the thermal emission of the asteroid's surface, which can be used to determine surface temperature by means of temperature-retrieval algorithms. The thermal behavior of areas of unusual albedo seen at the local scale can be related to physical properties that can provide information about the origin of those materials. Dawn's Visible and Infrared Mapping Spectrometer (VIR) hyperspectral cubes are used to retrieve surface temperatures, with high accuracy as long as temperatures are greater than 180 K. Data acquired in the Survey phase (23 July through 29 August 2011) show several unusual surface features: 1) high-albedo (bright) and low-albedo (dark) material deposits, 2) spectrally distinct ejecta, 3) regions suggesting finer-grained materials. Some of the unusual dark and bright features were re-observed by VIR in the subsequent High-Altitude Mapping Orbit (HAMO) and Low-Altitude Mapping Orbit (LAMO) phases at increased pixel resolution. To calculate surface temperatures, we applied a Bayesian approach to nonlinear inversion based on the Kirchhoff law and the Planck function. These results were cross-checked through application of alternative methods. Here we present temperature maps of several local-scale features that were observed by Dawn under different illumination conditions and different local solar times. Some bright terrains have an overall albedo in the visible as much as 40% brighter than surrounding areas. Data from the IR channel of VIR show that bright regions generally correspond to regions with lower thermal emission, i.e. lower temperature, while dark regions correspond to areas with higher thermal emission, i.e. higher temperature. This behavior confirms that many of the dark appearances in the VIS mainly reflect albedo variations. In particular, it is shown that during maximum daily insolation, dark features in the equatorial region may rise to temperatures greater than 270 K. However, individual features may show different thermal behaviours, as a result of differences in composition and/or structure (e.g, average grain size of the surface regolith, porosity, etc.). To complement the temperature and near-infrared emissivity derived from the infrared spectra, a separate work is devoted to calculate thermal inertia and other thermal properties using theoretical models which solve the heat equation for airless bodies, and model the distribution of temperatures due to surface roughness variations.

Tosi, F.↗

A Novel Non-Intrusive Method to Resolve the Thermal-Dome-Effect of Pyranometers: Radiometric Calibration and Implications

Traditionally the calibration equation for pyranometers assumes that the measured solar irradiance is solely proportional to the thermopile's output voltage; therefore only a single calibration factor is derived. This causes additional measurement uncertainties because it does not capture sufficient information to correctly account for a pyranometer's thermal effect. In our updated calibration equation, temperatures from the pyranometer's dome and case are incorporated to describe the instrument's thermal behavior, and a new set of calibration constants are determined, thereby reducing measurement uncertainties. In this paper, we demonstrate why a pyranometer's uncertainty using the traditional calibration equation is always larger than a-few-percent, but with the new approach can become much less than 1% after the thermal issue is resolved. The highlighted calibration results are based on NIST-traceable light sources under controlled laboratory conditions. The significance of the new approach lends itself to not only avoiding the uncertainty caused by a pyranometer's thermal effect but also the opportunity to better isolate and characterize other instrumental artifacts, such as angular response and non-linearity of the thermopile, to further reduce additional uncertainties. We also discuss some of the implications, including an example of how the thermal issue can potentially impact climate studies by evaluating aerosol's direct-radiative effect using field measurements with and without considering the pyranometer's thermal effect. The results of radiative transfer model simulation show that a pyranometer's thermal effect on solar irradiance measurements at the surface can be translated into a significant alteration of the calculated distribution of solar energy inside the column atmosphere.

Ji, Qiang↗

Effects of Long-Term Thermal Exposure on Commercially Pure Titanium Grade 2 Elevated-Temperature Tensile Properties

Elevated-temperature tensile testing of commercially pure titanium (CP Ti) Grade 2 was conducted for as-received commercially produced sheet and following thermal exposure at 550 and 650 K (531 and 711 F) for times up to 5000 h. The tensile testing revealed some statistical differences between the 11 thermal treatments, but most thermal treatments were statistically equivalent. Previous data from room temperature tensile testing was combined with the new data to allow regression and development of mathematical models relating tensile properties to temperature and thermal exposure. The results indicate that thermal exposure temperature has a very small effect, whereas the thermal exposure duration has no statistically significant effects on the tensile properties. These results indicate that CP Ti Grade 2 will be thermally stable and suitable for long-duration space missions.

Ellis, David L.↗

A Novel Nonintrusive Method to Resolve the Thermal Dome Effect of Pyranometers: Radiometric Calibration and Implications

Traditionally the calibration equation for pyranometers assumes that the measured solar irradiance is solely proportional to the thermopile s output voltage; therefore, only a single calibration factor is derived. This causes additional measurement uncertainties because it does not capture sufficient information to correctly account for a pyranometer s thermal effect. In our updated calibration equation, temperatures from the pyranometer's dome and case are incorporated to describe the instrument's thermal behavior, and a new set of calibration constants are determined, thereby reducing measurement uncertainties. In this paper, we demonstrate why a pyranometer's uncertainty using the traditional calibration equation is always larger than a few percent, but with the new approach can become much less than 1% after the thermal issue is resolved. The highlighted calibration results are based on NIST traceable light sources under controlled laboratory conditions. The significance of the new approach lends itself to not only avoiding the uncertainty caused by a pyranometer's thermal effect but also the opportunity to better isolate and characterize other instrumental artifacts, such as angular response and nonlinearity of the thermopile, to further reduce additional uncertainties. We also discuss some of the implications, including an example of how the thermal issue can potentially impact climate studies by evaluating aerosol s direct radiative effect using field measurements with and without considering the pyranometer s thermal effect. The results of radiative transfer model simulation show that a pyranometer s thermal effect on solar irradiance measurements at the surface can be translated into a significant alteration of the calculated distribution of solar energy inside the column atmosphere.

Ji. Q.↗

Reliability of CCGA 1152 and CCGA 1272 Interconnect Packages for Extreme Thermal Environments

Ceramic column grid array (CCGA) packages have been increasing in use based on their advantages of high interconnect density, very good thermal and electrical performance, and compatibility with standard surface-mount packaging assembly processes. CCGA packages are used in space applications such as in logics and microprocessor functions, telecommunications, flight avionics, and payload electronics. As these packages tend to have less solder joint strain relief than leaded packages, the reliability of CCGA packages is very important for short- and long-term space missions. Certain planetary satellites require operations of thermally uncontrolled hardware under extremely cold and hot temperatures with large diurnal temperature change from day to night. The planetary protection requires the hardware to be baked at +125 C for 72 hours to kill microbugs to avoid any biological contamination, especially for sample return missions. Therefore, the present CCGA package reliability research study has encompassed the temperature range of 185 to +125 C to cover various NASA deep space missions. Advanced 1152 and 1272 CCGA packaging interconnects technology test hardware objects have been subjected to ex treme temperature thermal cycles from 185 to +125 C. X-ray inspections of CCGA packages have been made before thermal cycling. No anomalous behavior and process problems were observed in the x-ray images. The change in resistance of the daisy-chained CCGA interconnects was measured as a function of increasing number of thermal cycles. Electrical continuity measurements of daisy chains have shown no anomalies, even until 596 thermal cycles. Optical inspections of hardware have shown a significant fatigue for CCGA 1152 packages over CCGA 1272 packages. No catastrophic failures have been observed yet in the results. Process qualification and assembly are required to optimize the CCGA assembly processes. Optical inspections of CCGA boards have been made after 258 and 596 thermal cycles. Corner columns have started showing significant fatigue per optical inspection results.

Ramesham, Rajeshuni↗

Toughened Thermal Blanket for MMOD Protection

Thermal blankets are used extensively on spacecraft to provide passive thermal control of spacecraft hardware from thermal extremes encountered in space. Toughened thermal blankets have been developed that greatly improve protection from hypervelocity micrometeoroid and orbital debris (MMOD) impacts. These blankets can be outfitted if so desired with a reliable means to determine the location, depth and extent of MMOD impact damage by incorporating an impact sensitive piezoelectric film. Improved MMOD protection of thermal blankets was obtained by adding selective materials at various locations within the thermal blanket. As given in Figure 1, three types of materials were added to the thermal blanket to enhance its MMOD performance: (1) disrupter layers, near the outside of the blanket to improve breakup of the projectile, (2) standoff layers, in the middle of the blanket to provide an area or gap that the broken-up projectile can expand, and (3) stopper layers, near the back of the blanket where the projectile debris is captured and stopped. The best suited materials for these different layers vary. Density and thickness is important for the disrupter layer (higher densities generally result in better projectile breakup), whereas a highstrength to weight ratio is useful for the stopper layer, to improve the slowing and capture of debris particles.

Christiansen, Eric L.↗

A Morphing Radiator for High-Turndown Thermal Control of Crewed Space Exploration Vehicles

Spacecraft designed for missions beyond low earth orbit (LEO) face a difficult thermal control challenge, particularly in the case of crewed vehicles where the thermal control system (TCS) must maintain a relatively constant internal environment temperature despite a vastly varying external thermal environment and despite heat rejection needs that are contrary to the potential of the environment. A thermal control system is in other words required to reject a higher heat load to warm environments and a lower heat load to cold environments, necessitating a quite high turndown ratio. A modern thermal control system is capable of a turndown ratio of on the order of 12:1, but for crew safety and environment compatibility these are massive multi-loop fluid systems. This paper discusses the analysis of a unique radiator design which employs the behavior of shape memory alloys (SMA) to vary the turndown of, and thus enable, a single-loop vehicle thermal control system for space exploration vehicles. This design, a morphing radiator, varies its shape in response to facesheet temperature to control view of space and primary surface emissivity. Because temperature dependence is inherent to SMA behavior, the design requires no accommodation for control, instrumentation, nor power supply in order to operate. Thermal and radiation modeling of the morphing radiator predict a turndown ranging from 11.9:1 to 35:1 independent of TCS configuration. Stress and deformation analyses predict the desired morphing behavior of the concept. A system level mass analysis shows that by enabling a single loop architecture this design could reduce the TCS mass by between 139 kg and 225 kg. The concept is demonstrated in proof-of-concept benchtop tests.

Cognata, Thomas J.↗

Combined Pressure and Thermal Window System for Space Vehicles

A window system for a vehicle comprising a pressure and thermal window pane, a seal system, and a retainer system. The pressure and thermal window pane may be configured to provide desired pressure protection and desired thermal protection when exposed to an environment around the vehicle during operation of the vehicle. The pressure and thermal window pane may have a desired ductility. The seal system may be configured to contact the pressure and thermal window pane to seal the pressure and thermal window pane. The retainer system may be configured to hold the seal system and the pressure and thermal window pane.

Svartstrom, Kirk Nils↗

Combined Pressure and Thermal Window System for Space Vehicles

A window system for a vehicle comprising a pressure and thermal window pane, a seal system, and a retainer system. The pressure and thermal window pane may be configured to provide desired pressure protection and desired thermal protection when exposed to an environment around the vehicle during operation of the vehicle. The pressure and thermal window pane may have a desired ductility. The seal system may be configured to contact the pressure and thermal window pane to seal the pressure and thermal window pane. The retainer system may be configured to hold the seal system and the pressure and thermal window pane.

Svartstrom, Kirk Nils↗

Microwave Thermal Propulsion

We have conducted research in microwave thermal propulsion as part of the space exploration access technologies (SEAT) research program, a cooperative agreement (NNX09AF52A) between NASA and Carnegie Mellon University. The SEAT program commenced on the 19th of February 2009 and concluded on the 30th of September 2015. The DARPA/NASA Millimeter-wave Thermal Launch System (MTLS) project subsumed the SEAT program from May 2012 to March 2014 and one of us (Parkin) served as its principal investigator and chief engineer. The MTLS project had no final report of its own, so we have included the MTLS work in this report and incorporate its conclusions here. In the six years from 2009 until 2015 there has been significant progress in millimeter-wave thermal rocketry (a subset of microwave thermal rocketry), most of which has been made under the auspices of the SEAT and MTLS programs. This final report is intended for multiple audiences. For researchers, we present techniques that we have developed to simplify and quantify the performance of thermal rockets and their constituent technologies. For program managers, we detail the facilities that we have built and the outcomes of experiments that were conducted using them. We also include incomplete and unfruitful lines of research. For decision-makers, we introduce the millimeter-wave thermal rocket in historical context. Considering the economic significance of space launch, we present a brief but significant cost-benefit analysis, for the first time showing that there is a compelling economic case for replacing conventional rockets with millimeter-wave thermal rockets.

Parkin, Kevin L. G.↗

Thermal Model Performance for the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in early 2019, is currently undergoing a series of system-level environmental tests to verify its workmanship and end-to-end functionality. As part of this series, the Optical Telescope Element and Integrated Science Instrument Module (OTIS) Cryo-Vacuum (CV) test, the most complex cryogenic test executed to date by NASA, has recently been completed at the Johnson Space Center’s Chamber A facility. The OTIS CV test was intended as a comprehensive test of the integrated instrument and telescope systems to fully understand its optical, structural, and thermal performance within its intended flight environment. Due to its complexity, extensive pre-test planning was required to ensure payload safety and compliance with all limits and constraints. A system-level pre-test thermal model was constructed which fully captured the behavior of the payload, ground support equipment, and surrounding test chamber. This thermal model simulated both the transient cooldown to and warmup from a 20K flight-like environment, as well as predicted the payload performance at cryo-stable conditions. The current work is a preliminary assessment of thermal model performance against actual payload response during the OTIS CV test. Overall, the thermal model performed exceedingly well at predicting schedule and payload response. Looking in depth, this work examines both the benefits and shortcomings of assumptions made pre-test to simplify model execution when compared against test data. It explores in detail the role of temperature-dependent emissivities during transition to cryogenic temperatures, as well as the impact that model geometry simplifications have on tracking of critical hardware limits and constraints. This work concludes with a list of recommendations to improve the accuracy of thermal modeling for future large cryogenic tests. It is hoped that the insight gained from the OTIS CV test thermal modeling will benefit planning and execution for upcoming cryogenic missions.

Yang, Kan↗

Mid and Thermal Infrared Remote Sensing at the Jet Propulsion Laboratory

The mid and thermal infrared (MTIR) for the Earth surface is defined between 3 and 14µm. In the outer solar system, objects are colder and their Planck response shifts towards longer wavelengths. Hence for these objects (e.g. icy moons, polar caps, comets, Europa), the thermal IR definition usually stretches out to 50µm and beyond. Spectroscopy has been a key part of this scientific exploration because of its ability to remotely determine elemental and mineralogical composition. Many key gas species such as methane, ammonia, sulfur, etc. also have vibrational bands which show up in the thermal infrared spectrum above the background response. Over the past few decades, the Jet Propulsion Laboratory has been building up a portfolio of technology to capture the MTIR for various scientific applications. Three recent sensors are briefly reviewed: The airborne Hyperspectral thermal emission spectrometer (HyTES), the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) and Mars Climate Sounder (MCS)/DIVINER. Each of these sensors utilize a different technology to provide a remote sensing product based on MTIR science. For example, HyTES is a push-brooming hyperspectral imager which utilizes a large format quantum well infrared photodetector (QWIP). The goal is to transition this to a new complementary barrier infrared photodetector (CBIRD) with a similar long wave cut-off and increased sensitivity. ECOSTRESS is a push-whisk Mercury Cadmium Telluride (MCT) based high speed, multi-band, imager which will eventually observe and characterize plant/vegetation functionality and stress index from the International Space Station (ISS) across the contiguous United States (CONUS). MCS/DIVINER utilizes thermopile technology to capture the thermal emission from the polar caps and shadow regions of the moon. Each sensor utilizes specific JPL technology to capture unique science. similar long wave cut-off and increased sensitivity. ECOSTRESS is a push-whisk Mercury Cadmium Telluride (MCT) based high speed, multi-band, imager which will eventually observe and characterize plant/vegetation functionality and stress index from the International Space Station (ISS) across the contiguous United States (CONUS). MCS/DIVINER utilizes thermopile technology to capture the thermal emission from the polar caps and shadow regions of the moon. Each sensor utilizes specific JPL technology to capture unique science.

Johnson, William R.↗

Mars 2020 Mobility Actuator Thermal Testing and Model Correlation

This paper describes the thermal testing and model correlation of a mobility actuator planned for use on the Mars 2020 Rover. The mobility actuator is identical to those which have been successfully flown and operated on the Mars Science Laboratory (MSL) Curiosity rover since its successful landing on Mars in August of 2012. The actuator consists of a motor, brake, and encoder paired with a four stage planetary gear box. In this thermal test, the actuator was instrumented with a number of thermocouples on both the interior and exterior of the gearbox. Heaters and a cold plate were used to generate thermal gradients across the actuator in vacuum, low pressure GN2, and low pressure CO2 environments in an effort to correlate a thermal model and develop a better understanding of how heat flows through the mechanism. This testing resulted in the successful model correlation of a simplified thermal model, and yielded important insights regarding the conductance of ball bearings and gear-to-gear contact. Ball bearing thermal conductance in a low pressure environment can be estimated by using correlations for vacuum thermal conductance along with a multiplier to account for increased gas conduction, and gear-to-gear conductance can be estimated by accounting for gas and grease conduction between two gears.

Novak, Keith↗

Multi-Angle Imager for Aerosols Thermal Control System

The Multi-Angle Imager for Aerosols (MAIA) Thermal Control System is a NASA funded instrument that will collect data to help characterize airborne particulate matter over a number of population centers across the globe using multi-angle spectropolarimetric imagery. The data collected by MAIA will facilitate assessments of the impacts of different types of particulate matter on adverse health outcomes. MAIA is a hosted payload meant to operate in a near-circular sun-synchronous polar orbit, with a mean altitude between 600 km and 850 km. The nominal on-orbit mission design lifetime is three years. Temperature control of the MAIA instrument is accomplished with a combination of passive radiators and heaters. The focal plane module (FPM) is cooled to ≤ 235K with a disc shaped radiator that faces the anti-sun side of the sun-synchronous orbit. The temperature of the MAIA cameras and associated electronics is controlled with a cylindrical shaped radiator that projects a near constant area in the nadir direction as the cameras rotate. A noteworthy feature of the MAIA thermal control system design is the novel, low cost, rotationally articulating thermal strap used to transfer heat from the FPMs to their associated FPM Radiator. The strap spans one of the axes of rotation, sweeping out an arc of approximately 60° as the instrument operates. A prototype of the articulating thermal strap was life tested to 260,000 cycles with no signs of significant degradation. An overview of the MAIA thermal control system baseline design is presented, with focus on its novel aspects, including life testing of the prototype articulating thermal strap. In addition, a discussion of the considerations involved in designing a thermal control system for a hosted instrument is provided.

Rosas, Rogelio↗

Role of Compressive Viscosity and Thermal Conductivity on the Damping of Slow Waves in Coronal Loops with and Without Heating–Cooling Imbalance

In the present article, we derive a new dispersion relation for slow magnetoacoustic waves invoking the effect of thermal conductivity, compressive viscosity, radiation, and an unknown heating term along with the consideration of heating–cooling imbalance from linearized MHD equations. We solve the general dispersion relation to understand the role of compressive viscosity and thermal conductivity in the damping of slow waves in coronal loops with and without heating–cooling imbalance. We have analyzed the wave damping for the range of loop length L=50--500 Mm, temperature T=5--30 MK, and density ρ=10^(−11)--10^(−9) kg/cu.m. It was found that the inclusion of compressive viscosity along with thermal conductivity significantly enhances the damping of the fundamental mode oscillations in shorter (e.g. L=50 Mm) and super-hot (T>10 MK) loops. However, the role of viscosity in the damping is insignificant in longer (e.g. L=500 Mm) and hot loops (T≤10 MK) where, instead, thermal conductivity along with the presence of heating–cooling imbalance plays a dominant role. For shorter loops at a super-hot regime of temperature, the increment in the loop density substantially enhances the damping of the fundamental modes due to thermal conductivity when viscosity is absent, however, when the compressive viscosity is added the increase in density substantially weakens the damping. Thermal conductivity alone is found to play a dominant role in longer loops at lower temperatures (T≤10 MK), while compressive viscosity dominates the damping at super-hot temperatures (T>10 MK) in shorter loops. The predicted scaling law between damping time (τ) and wave period (P) is found to better match the observed SUMER (Solar Ultraviolet Measurements of Emitted Radiation) oscillations when the heating–cooling imbalance is taken into account in addition to thermal conductivity and compressive viscosity for the damping of the fundamental slow mode oscillations.

Abhinav Prasad↗

Delta Method Application for the Correlation of IR Detector Thermal Parasitic Loads with Statistically Accurate Results

The Linear Etalon Imaging Spectral Array (LEISA) is a cryogenic IR detector that is passively cooled below 110K. LEISA is part of the L’Ralph instrument, which is going on the Lucy mission, with planned flyby’s of the Trojan asteroids around 5.5 AU. One of the primary thermal challenges is to successfully quantify each significant parasitic heat flow value with statistical certainty.Simulation of flight-like thermal environments and correlation of thermal models is an important part of this challenge, which can be critical for thermally sensitive systems such as cryogenic detectors that are passively cooled. It is common practice during TVAC to achieve several thermal balance points and then to correlate several design variables in order to achieve the closest match to all balance points tested. This approach lends itself to high levels of uncertainty in the correlated values due to the cumulative effect of absolute temperature uncertainty and differences between the sensors used for the measurement. Accuracy can be improved with the use of more accurate sensors, by calibrating all sensors with respect to each other, and by using Zero-Q methodologies, all of which add cost and complexity to the test.The Delta Method uses the difference in temperature caused by the changes in the boundary conditions to calculate heat flows and/or thermal resistances across temperature differentials. This eliminates the problem of high uncertainties with absolute temperature measurements, and yields statistically accurate results down to the sensor resolution of 1mK at < 100K, by taking the sensor’s calibration errors out of the equation. During testing, this method relies on parametric variations around an initial balance point, by varying the boundary conditions of the different parasitic heat sources. The Delta Method, as well as its application on the LEISA thermal test, will be discussed in detail.

Daniel G. Bae↗

High Performance Thermal Switch for Lunar and Planetary Surface Extreme Environments

This paper describes a high performance thermal switch for lunar/planetary extreme environments. This device has been given the name Reverse-Operation DTE Thermal Switch (or ROD-TSW). Two different prototypes were designed, built, and tested. Their basis of operation is the mating/de-mating of parallel flat metal surfaces driven by the differential thermal expansion (DTE) between mid-to-high CTE metal/polymer or metal-only end-pieces and a low CTE, low thermal conductivity (k) metal/polymer support rod. The requirements were to be fully ON above 300 K and fully OFF below 260 K. A series of four tests were carried out to verify/qualify the prototypes. In the first (non-vacuum) test, the thermal switches were cooled with freeze-spray and the non-conductive rod in the OFF thermal path allowed electrical resistance to confirm the 273 K as-designed ON/OFF actuation temperature. In the second (vacuum) test, a calibrated Q-meter was used, which indicated 5 W/K ON, 0.002 W/K OFF conductance (2500:1 ON/OFF ratio). To increase readiness to TRL6, a vibration test with pre/post thermal cycling followed by a 36-day test in a relevant environment were also carried out. This paper describes the development program and on-going related work at JPL.

Bugby, David C↗

Comparing Cumulative Flight Thermal Fatigue to Ground Test Results for Memory Components on the Mars Curiosity Rover

This paper explores the methods used to examine Mars Curiosity Rover’s flight temperature data to the Package Qualification and Verification (PQV) accelerated thermal cycle life test data in response to flight anomalies. The redundant Rover Compute Element (RCE-A, B) has experienced an inability to mount the flash memory several times. The leading cause of these anomalies is likely the loss of electrical connectivity, which is theorized to be due to cracks on the memory component solder joints by thermal cycle fatigue. To investigate this theory, the number of thermal cycles accumulated in flight was compared to PQV accelerated thermal cycle life test data. The goal of this study was to inform mission operations of the risk associated with thermal cycling damage on the RCE. However, since the RCE-B does not have continuous temperature data from the Platinum Resistance Thermometer (PRT) closest to the flash memory, a model was made to correlate continuous data from two other nearby sensors on the RCE-B to the noncontiguous sensor. Using the Rainflow Counting Algorithm, the reconstituted data was converted into the number of equivalent thermal cycles. The Coffin-Manson Equation was used to compare flight thermal cycles to the PQV test. The accelerated life test showed cracking on the memory component solder joints after 500 cycles of 80°C temperature excursions. This study found that the RCE-A and RCE-B have undergone an equivalent of 144 and 430 cycles of 80°C temperature excursions during flight, respectively.

Berger, Lindsey N↗