Abstract
A standard radio frequency coaxial connector is modified so that a plastic insulating sleeve can be mounted in the wall of a vacuum chamber. This eliminates ground loops and interference from cable connections.
Keep this discovery
Explore connections, maps & timelines
Weiner, D.. 1964-05-01. Modified RF coaxial connector ends vacuum chamber wiring problem. https://ntrs.nasa.gov/citations/19640000006