Search NASA⌕ Search

NASA NTRS · 19720041582

Reentry heating and flow fields for Space Shuttle Orbiter at high angle of attack.

Abstract

Rarefied flow fields and heating rates are calculated by a Monte Carlo direct simulation technique for several shuttle orbiter configurations at angles of attack between 40 and 60 deg. Continuum inviscid flow fields are determined by 2-D unsteady and 3-D steady finite-difference/artificial viscosity techniques used in combination with a 2-D shock layer analysis method. Continuum viscous flow fields and heating rates are computed by a boundary-layer integral matrix technique and an aerodynamic heating method.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rochelle, W. C., Roberts, B. B., D'Attorre, L., Vogenitz, F. W.. 1972-04-01. Reentry heating and flow fields for Space Shuttle Orbiter at high angle of attack.. https://ntrs.nasa.gov/citations/19720041582

Cite the original work for its findings. Save a collection to share your selection of sources.