NASA NTRS ยท 19730003879
Cryogenic insulation development
Abstract
Multilayer insulations for long term cryogenic storage are described. The development effort resulted in an insulation concept using lightweight radiation shields, separated by low conductive Dacron fiber tufts. The insulation is usually referred to as Superfloc. The fiber tufts are arranged in a triangular pattern and stand about .040 in. above the radiation shield base. Thermal and structural evaluation of Superfloc indicated that this material is a strong candidate for the development of high performance thermal protection systems because of its high strength, purge gas evacuation capability during boost, its density control and easy application to a tank.
Keep this discovery
Explore connections, maps & timelines
Leonhard, K. E.. 1972-07-28. Cryogenic insulation development. https://ntrs.nasa.gov/citations/19730003879
Cite the original work for its findings. Save a collection to share your selection of sources.