Abstract
Finite difference computer techniques have been used to calculate the detailed performance of air to air two-dimensional ejectors with symmetric variable area mixing sections and coaxial coverging primary nozzles. The analysis of the primary nozzle assumed correct expansion of the flow and is suitable for subsonic and slightly supersonic velocity levels. The variation of the mixing section channel walls is assumed to be gradual so that the static pressure can be assumed uniform on planes perpendicular to the axis. A test program was run to provide two-dimensional ejector test data for verification of the computer analysis. A primary converging nozzle with a discharge geometry of 0.125 inch x 8.0 inch was supplied with 600 SCFM of air at about 35 psia and 180 F. This nozzle was combined with two mixing section geometries with throat sizes of 1.25 inch x 8.0 inch and 1.875 inch x 8.0 inch and was tested at a total of 11 operating points.