Abstract
The limitations of chamber tests with regard to the molecular contamination of a spacecraft undergoing vacuum test were examined. The molecular flow conditions existing in the chamber and the parameters dictating the degree of contamination were analyzed. Equations and graphs were developed to show the fraction of molecules returning to the spacecraft out of those emitted and to show other chamber flow parameters as a function of chamber and spacecraft surface molecular pumping and geometric configuration. Type and location of instruments required to measure the outgassing, the degree of contamination, and the returning flows are also discussed.
Keep this discovery
Explore connections, maps & timelines
Scialdone, J. J.. 1973-05-01. Determination of molecular contamination performance for space chamber tests. https://ntrs.nasa.gov/citations/19730015537