Search NASAโŒ• Search

NASA NTRS ยท 19730015537

Determination of molecular contamination performance for space chamber tests

Abstract

The limitations of chamber tests with regard to the molecular contamination of a spacecraft undergoing vacuum test were examined. The molecular flow conditions existing in the chamber and the parameters dictating the degree of contamination were analyzed. Equations and graphs were developed to show the fraction of molecules returning to the spacecraft out of those emitted and to show other chamber flow parameters as a function of chamber and spacecraft surface molecular pumping and geometric configuration. Type and location of instruments required to measure the outgassing, the degree of contamination, and the returning flows are also discussed.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Scialdone, J. J.. 1973-05-01. Determination of molecular contamination performance for space chamber tests. https://ntrs.nasa.gov/citations/19730015537

Cite the original work for its findings. Save a collection to share your selection of sources.