Search NASA⌕ Search

NASA NTRS · 19750008413

A three-electrode streamer chamber

Abstract

A three electrode streamer chamber has been designed with basic components consisting of two glass boxes with overall dimensions 1.00 x 500 x 200 cu m filled with neon at 1 atm. Serving as a high voltage pulse source is a nanosecond voltage pulse generator with cutoff discharges at 16 atm nitrogen pressure. The discharges are designed for obtaining an adjustable pulse with an amplitude of 600 kV and a nanosecond pump. To match the chamber electrodes with the oscillator, the electrodes are manufactured in the shape of a three-wire strip line. The cutoff discharger plug-in and the operating instructions are also described here.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nurgozhin, N. N.. 1975-01-01. A three-electrode streamer chamber. https://searchnasa.com/record/nasa%3A19750008413/a-three-electrode-streamer-chamber