NASA NTRS ยท 19750019233
A short static-pressure probe design for supersonic flow
Abstract
A static-pressure probe design concept was developed which has the static holes located close to the probe tip and is relatively insensitive to probe angle of attack and circumferential static hole location. Probes were constructed with 10 and 20 deg half-angle cone tips followed by a tangent conic curve section and a tangent cone section of 2, 3, or 3.5 deg, and were tested at Mach numbers of 2.5 and 4.0 and angles of attack up to 12 deg. Experimental results indicate that for stream Mach numbers of 2.5 and 4.0 and probe angle of attack within + or - 10 deg, values of stream static pressure can be determined from probe calibration to within about + or - 4 percent. If the probe is aligned within about 7 deg of the flow experimental results indicated, the stream static pressures can be determined to within 2 percent from probe calibration.
Keep this discovery
Explore connections, maps & timelines
Pinckney, S. Z.. 1975-07-01. A short static-pressure probe design for supersonic flow. https://ntrs.nasa.gov/citations/19750019233
Cite the original work for its findings. Save a collection to share your selection of sources.