Abstract
Flight data from a 15.8 mm OD, 760 mm long, axial-groove, methane cryogenic heat pipe verified successful priming and operation during six min of zero-g time. The nominal power applied to the evaporator was 60-w for the first 60 sec of zero-g time, 14 w for the next 270 sec, and 25 w for the last 20 sec of flight. The heat pipe condenser was mounted into an aluminum heat sink which was cooled to 103 K at launch and increased in temperature to 128 K by the end of the flight. Ground test data obtained for the flight heat pipe, together with theoretical predictions, indicate a zero-g heat transport capability of 3500 to 4000 w-cm in the 100-125 K temperature range.
Keep this discovery
Explore connections, maps & timelines
Harwell, W., Quadrini, J., Sherman, A., Mcintosh, R.. 1975-05-01. Cryogenic heat pipe experiment - Flight performance onboard a sounding rocket. https://ntrs.nasa.gov/citations/19750048800