NASA NTRS ยท 19760010930
Lunar sample analysis
Abstract
Room temperature internal friction (Q sup-1) values of the 0.00002-0.00003 range were achieved with lunar rock 70215,85 by thorough outgassing procedures in ultrahigh vacuum. Results are presented on the temperature dependence of Q sup -1 as measured in the range 25 C to 600 C along with some data on the change in Q sup -1 with pressure in ultrahigh vacuum. The temperature dependence shows the existence of an internal friction peak at around 200 C followed at high temperatures by an extensive region with flat Q sup -1 (approximately 0.001); the work at ultrahigh vacuum shows decreases in the internal friction with decreases in ambient pressure even in the range 10 to the -8 to 10 to the -10 power torr.
Keep this discovery
Explore connections, maps & timelines
Tittmann, B. R.. 1976-01-31. Lunar sample analysis. https://ntrs.nasa.gov/citations/19760010930