NASA NTRS ยท 19760016591
Energy Conversion Alternatives Study (ECAS), General Electric Phase 1. Volume 1: Executive summary
Abstract
A data base for the comparison of advanced energy conversion systems for utility applications using coal or coal-derived fuels was developed. Estimates of power plant performance (efficiency), capital cost, cost of electricity, natural resource requirements, and environmental intrusion characteristics were made for ten advanced conversion systems. Emphasis was on the energy conversion system in the context of a base loaded utility power plant. All power plant concepts were premised on meeting emission standard requirements. A steam power plant (3500 psig, 1000 F) with a conventional coal-burning furnace-boiler was analyzed as a basis for comparison. Combined cycle gas/steam turbine system results indicated competitive efficiency and a lower cost of electricity compared to the reference steam plant. The Open-Cycle MHD system results indicated the potential for significantly higher efficiency than the reference steam plant but with a higher cost of electricity.
Keep this discovery
Explore connections, maps & timelines
Corman, J. C.. 1976-02-01. Energy Conversion Alternatives Study (ECAS), General Electric Phase 1. Volume 1: Executive summary. https://ntrs.nasa.gov/citations/19760016591