NASA NTRS ยท 19760054749
Graded-porosity heat-pipe wicks
Abstract
To maximize the capacity of a nonarterial heat pipe, a wick is considered whose porosity is allowed to vary axially along its length. At every axial location the porosity is set no lower than required to maintain the wick in a nearly saturated state under the maximum heat-transport rate. The result is a wick whose permeability is everywhere as high as possible. The differential equation that governs the optimum porosity variation is solved numerically between a condenser-end boundary condition that just prevents a liquid slug or puddle in the vapor spaces and an evaporator-end boundary condition that just prevents circumferential groove dry-up. Experimental performance measurements for an ammonia heat pipe are presented.
Keep this discovery
Explore connections, maps & timelines
Eninger, J. E.. 1976-07-01. Graded-porosity heat-pipe wicks. https://ntrs.nasa.gov/citations/19760054749