NASA NTRS · 19780031913
Estimating surface temperature in forced convection nucleate boiling - A simplified method
Abstract
A simplified expression to estimate surface temperatures in forced convection boiling was developed using a liquid nitrogen data base. Using the principal of corresponding states and the Kutateladze relation for maximum pool boiling heat flux, the expression was normalized for use with other fluids. The expression was applied also to neon and water. For the neon data base, the agreement was acceptable with the exclusion of one set suspected to be in the transition boiling regime. For the water data base at reduced pressure greater than 0.05 the agreement is generally good. At lower reduced pressures, the water data scatter and the calculated temperature becomes a function of flow rate.
Keep this discovery
Explore connections, maps & timelines
Hendricks, R. C., Papell, S. S.. 1977-08-01. Estimating surface temperature in forced convection nucleate boiling - A simplified method. https://ntrs.nasa.gov/citations/19780031913
Cite the original work for its findings. Save a collection to share your selection of sources.