Search NASA⌕ Search

NASA NTRS · 19780038587

Studies with the USF/NASA toxicity screening test method - Oxygen concentrations with various test conditions

Abstract

Continuing efforts to increase the versatility of the USF/NASA toxicity screening test method have included the use of different test conditions in order to simulate various fire environments. The use of air flow at flow rates of 16 to 48 ml/sec maintains oxygen concentrations above 19 percent throughout the 30 min exposure period, compared to above 16 percent without forced air flow. These levels of oxygen are well within the tolerance range of mice, and approach the oxygen levels found in many real fire situations. Proposed minimum oxygen levels based on experience with rats are unduly restrictive on the use of other species such as mice, and tend to eliminate the cost savings which may more than justify the selection of mice.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hilado, C. J., Cumming, H. J., Solis, A. N.. 1977-11-01. Studies with the USF/NASA toxicity screening test method - Oxygen concentrations with various test conditions. https://ntrs.nasa.gov/citations/19780038587

Cite the original work for its findings. Save a collection to share your selection of sources.