Search NASA⌕ Search

NASA NTRS · 19790067974

Low cost cylindrical converter for measuring lead efficiency

Abstract

A low cost cylindrical thermionic converter has been designed, fabricated, and tested for use in a NASA-JPL program to directly measure converter lead efficiencies using various electrode materials and surfaces. Efficiency measurements are made using input emitter heater power, output power at the leads, and calculated values of the parasitic losses that would not be present in the application configuration. This information can be used to predict the performance characteristics of the advanced converters currently under development. A series of five converters has been tested. Both structured and smooth molybdenum collectors have been used. Emitters included smooth molybdenum, smooth rhenium, and microstructured rhenium. Cesium pressure families of current-voltage curves are presented for emitter temperatures of 1600, 1700, and 1800 K, along with measured efficiencies as a function of converter current densities for each temperature.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hatch, G. L., Nakata, L., Britt, E. J.. 1979-01-01. Low cost cylindrical converter for measuring lead efficiency. https://ntrs.nasa.gov/citations/19790067974