Abstract

High accuracy is obtained by combining analog and digital corrections. Proximity-sensor linearization circuit has two stages. First-stage linearization is accurate to about 3 percent; accuracy of final output is better than 0.5 percent. By modifying contents of the Programable Read-Only Memory (PROM), circuit can also be used to derive a nonlinear output.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Waldeck, G. C., Dendy, J. B.. 1982-11-01. Two-Stage Linearization Circuit. https://ntrs.nasa.gov/citations/19810000125