Search NASAโŒ• Search

NASA NTRS ยท 19820021137

Reconfiguring redundancy management

Abstract

A redundancy management system is described wherein input signals from a sensor are provided redundantly in parallel so that a primary control signal may be selected. Median value signals for groups of three sensors are detected in median value selectors of selection filter. The detected median value signals are then also compared in a subtractor/comparator to determine whether any of them exceed the others by an amount greater than the signal level for a failed sensor. If so, the exceeding detected medium value signal is sent to a control computer as the primary control signal. If not, the lowest level detected medium value signal is sent as the primary control signal.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gelderloos, H. J. C.. 1982-04-27. Reconfiguring redundancy management. https://ntrs.nasa.gov/citations/19820021137

Cite the original work for its findings. Save a collection to share your selection of sources.