Abstract
A redundancy management system is described wherein input signals from a sensor are provided redundantly in parallel so that a primary control signal may be selected. Median value signals for groups of three sensors are detected in median value selectors of selection filter. The detected median value signals are then also compared in a subtractor/comparator to determine whether any of them exceed the others by an amount greater than the signal level for a failed sensor. If so, the exceeding detected medium value signal is sent to a control computer as the primary control signal. If not, the lowest level detected medium value signal is sent as the primary control signal.
Keep this discovery
Explore connections, maps & timelines
Gelderloos, H. J. C.. 1982-04-27. Reconfiguring redundancy management. https://ntrs.nasa.gov/citations/19820021137