Search NASAโŒ• Search

NASA NTRS ยท 19820040332

Echelle spectrographs at grazing incidence

Abstract

It is shown that by using the conical diffraction mount, existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft X rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV, has a primary mirror and an entrance slit to the spectrograph. The system has a resolution of 10,000, operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The X-ray spectrograph uses objective gratings to obtain spectral resolution of 28,000 over any factor of 2 in. wavelength. It operates to wavelengths as short as 4 A.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Cash, W.. 1982-02-15. Echelle spectrographs at grazing incidence. https://ntrs.nasa.gov/citations/19820040332