NASA NTRS ยท 19820040332
Echelle spectrographs at grazing incidence
Abstract
It is shown that by using the conical diffraction mount, existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft X rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV, has a primary mirror and an entrance slit to the spectrograph. The system has a resolution of 10,000, operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The X-ray spectrograph uses objective gratings to obtain spectral resolution of 28,000 over any factor of 2 in. wavelength. It operates to wavelengths as short as 4 A.
Keep this discovery
Explore connections, maps & timelines
Cash, W.. 1982-02-15. Echelle spectrographs at grazing incidence. https://ntrs.nasa.gov/citations/19820040332
Cite the original work for its findings. Save a collection to share your selection of sources.