Abstract

Hotspots eliminated by lining inner wall. Distribution of heat transfer liquid in heat-pipe evaporator improved by lining inner wall with layer of sintered metal. Sintered layer takes place of layer of screen wick formerly sintered or bonded to wall. Since sintered layer always full of liquid, no hotspot of type that previously arose where former screen wick did not fit properly against wall.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ernst, D. M., Eastman, G. Y.. 1985-01-01. Sintered Lining for Heat-Pipe Evaporator. https://ntrs.nasa.gov/citations/19840000118