A new inverter topology using GTO commutation

Abstract

A new N-phase, forced commutated bridge inverter topology has been developed wherein a single Gate Turn Off Thyristor (GTO) is used to commutate each of 2N main Thyristors (SCRs). Since, for most applications, the primary loss mechanism is the SCR forward drop, very high efficiencies are possible. Compared with conventional pure SCR and pure GTO inverters, cost per kW is lower - in the former case due to the large cost differential between GTOs and SCRs. Other advantages of the new inverter include high power density, low switching losses and stresses, modulation flexibility and amenability to high voltage and high frequency operation.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rippel, W. E.. 1983-01-01. A new inverter topology using GTO commutation. https://ntrs.nasa.gov/citations/19840047428