A procedure for checking whether small changes in a structure have the potential for significant enhancements of its vibration control system is described. The first step in the procedure consists of the calculation of the sensitivity of the required strength of the control system to small changes in structural parameters. The second step consists of the optimization of the structural parameters to produce maximal reduction in required control system strength with minimal change in the structure. The procedure has been demonstrated for a flexible beam supported by four cables and controlled by a rate feedback single-colocated force-actuator velocity-sensor pair. Large changes in control strength requirement were obtained with small structural modifications. Analytical predictions of such effects have also been validated experimentally.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Haftka, R. T., Martinovic, Z. N., Hallauer, W. L., Jr.. 1984-01-01. Enhanced vibration controllability by minor structural modifications. https://ntrs.nasa.gov/citations/19840048941