Search NASAโŒ• Search

NASA NTRS ยท 19850010642

Static internal performance of a two-dimensional convergent nozzle with thrust-vectoring capability up to 60 deg

Abstract

An investigation was conducted at wind-off conditions in the static-test facility of the Langley 16-Foot Transonic Tunnel to determine the internal performance characteristics of a two-dimensional convergent nozzle with a thrust-vectoring capability up to 60 deg. Vectoring was accomplished by a downward rotation of a hinged upper convergent flap and a corresponding rotation of a center-pivoted lower convergent flap. The effects of geometric thrust-vector angle and upper-rotating-flap geometry on internal nozzle performance characteristics were investigated. Nozzle pressure ratio was varied from 1.0 (jet off) to approximately 5.0.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Leavitt, L. D.. 1985-02-01. Static internal performance of a two-dimensional convergent nozzle with thrust-vectoring capability up to 60 deg. https://ntrs.nasa.gov/citations/19850010642