Search NASA⌕ Search

NASA NTRS · 19850025828

Energy efficient engine. Fan and quarter-stage component performance report

Abstract

The fan configuration for the general Electric/NASA Energy Efficient Engine was selected following an extensive preliminary design study. The fan has an inlet radius ratio of 0.342 and a specific flowrate of 208.9 Kg/sec/sq. m (42.8 1bm/sec/sq. ft). The design corrected tip speed is 411.5 m/sec (1350 ft/sec) producing a bypass flow total-pressure ratio of 1.65 and a core flow total-pressure ratio of 1.6. The design bypass ratio is 6.8. The aerodynamic design point corresponds to the maximum climb power setting at Mach 0.8 and 10.67 Km (35,000 ft) altitude. The fully-instrumented fan component was tested in the Lynn Large Fan Test Facility in 1981. The overall performance results, reported herein, showed excellent fan performance with the fan meeting all of its component test goals of flow, efficiency and stall margin.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Cline, S. J., Halter, P. H., Kutney, J. T., Jr., Sullivan, T. J.. 1983-01-01. Energy efficient engine. Fan and quarter-stage component performance report. https://ntrs.nasa.gov/citations/19850025828

Cite the original work for its findings. Save a collection to share your selection of sources.