Abstract
A large butterfly valve (1.37 m diam) was acoustically tested to measure the noise generated and propagating in both the upstream and downstream directions. The experimental investigation used wall mounted pressure transducers to measure the fluctuating component of the pipe static pressure upstream and downstream of the valve. Microphones upstream of the pipe inlet and located in a plenum were used to measure the noise radiated from the valve in the upstream direction. Comparison of the wall pressure downstream of the valve to a prediction were made. Reasonable agreement was obtained with the valve operating at a choked condition. The noise upstream of the valve is 30 dB less than that measured downstream.
Keep this discovery
Explore connections, maps & timelines
Huff, Ronald G.. 1987-01-01. Noise generated by flow through large butterfly valves. https://ntrs.nasa.gov/citations/19870007153
Cite the original work for its findings. Save a collection to share your selection of sources.