Abstract

During the conceptual design phase a 20-kHz power distribution system was selected as the reference for the Space Station. The system is single-phase 400 VRMS, with a sinusoidal wave form. The initial user power level will be 75 kW with growth to 300 kW. The high-frequency system selection was based upon considerations of efficiency, weight, safety, ease of control, interface with computers, and ease of paralleling for growth. Each of these aspects will be discussed as well as the associated trade-offs involved. An advanced development program has been instituted to accelerate the maturation of the high-frequency system. Some technical aspects of the advanced development will be discussed.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hansen, Irving G., Sundberg, Gale R.. 1986-01-01. Space Station 20-kHz power management and distribution system. https://ntrs.nasa.gov/citations/19870049639