NASA NTRS · 19880004229
Conservatism implications of shock test tailoring for multiple design environments
Abstract
A method for analyzing shock conservation in test specifications that have been tailored to qualify a structure for multiple design environments is discussed. Shock test conservation is qualified for shock response spectra, shock intensity spectra and ranked peak acceleration data in terms of an Index of Conservation (IOC) and an Overtest Factor (OTF). The multi-environment conservation analysis addresses the issue of both absolute and average conservation. The method is demonstrated in a case where four laboratory tests have been specified to qualify a component which must survive seven different field environments. Final judgment of the tailored test specification is shown to require an understanding of the predominant failure modes of the test item.
Keep this discovery
Explore connections, maps & timelines
Baca, Thomas J., Bell, R. Glenn, Robbins, Susan A.. 1987-10-01. Conservatism implications of shock test tailoring for multiple design environments. https://ntrs.nasa.gov/citations/19880004229