NASA NTRS ยท 19890004389
Flowmeter evaluation for on-orbit operations
Abstract
Various flowmetering concepts were flow tested to characterize the relative capabilities and limitations for on-orbit fluid-transfer operations. Performance results and basic operating principles of each flowmetering concept tested are summarized, and basic considerations required to select the best flowmeter(s) for fluid system application are discussed. Concepts tested were clamp-on ultrasonic, area averaging ultrasonic, offset ultrasonic, coriolis mass, vortex shedding, universal venturi tube, turbine, bearingless turbine, turbine/turbine differential-pressure hybrid, dragbody, and dragbody/turbine hybrid flowmeters. Fluid system flowmeter selection considerations discussed are flowmeter performance, fluid operating conditions, systems operating environments, flowmeter packaging, flowmeter maintenance, and flowmeter technology. No one flowmetering concept tested was shown to be best for all on-orbit fluid systems.
Keep this discovery
Explore connections, maps & timelines
Baird, R. S.. 1988-08-01. Flowmeter evaluation for on-orbit operations. https://ntrs.nasa.gov/citations/19890004389
Cite the original work for its findings. Save a collection to share your selection of sources.