NASA NTRS ยท 19890013578
Improvements to the CONTINUE feature in transient analysis
Abstract
The CONTINUE feature in transient analysis as implemented in the standard release of COSMIC/NASTRAN has inherent errors associated with it. As a consequence, the results obtained by a CONTINUEd restart run do not, in general, match the results that would be obtained in a single run without the CONTINUE feature. These inherent errors were eliminated by improvements to the restart logic that were developed by RPK Corporation and that are available on all RPK-supported versions of COSMIC/NASTRAN. These improvements ensure that the results of a CONTINUEd transient analysis run are the same as those of a non-CONTINUEd run. In addition, the CONTINUE feature was extended to transient analysis involving uncoupled modal equations. The improvements and enhancement were illustrated by examples.
Keep this discovery
Explore connections, maps & timelines
Pamidi, P. R.. 1989-03-01. Improvements to the CONTINUE feature in transient analysis. https://ntrs.nasa.gov/citations/19890013578
Cite the original work for its findings. Save a collection to share your selection of sources.