Search NASA⌕ Search

NASA NTRS · 19910030911

TOPEX microwave radiometer system calibration - Refining the SMMR heritage

Abstract

A modified version of the Scanning multichannel Microwave Radiometer (SMMR) will be used for wet tropospheric path-delay corrections to the TOPEX/POSEIDON radar altimeter measurements. A number of the sources of calibration problems encountered by SMMR onboard the Seasat and Nimbus-7 platforms have been identified, and appropriate corrections have been attempted. Calibration hardware corrections include a more representative modeling of the microwave losses and reflections, and a reduction in the thermal gradients expected across this hardware through the use of radomes and sun shades and the choice of pertinent orbit parameters. Antenna calibration corrections include a postlaunch fine tuning of the antenna pattern correction algorithm to accommodate small errors in the prelaunch antenna pattern measurements. This is accomplished by overpasses of ground-based, upward-looking water vapor radiometers. An absolute calibration accuracy of 1.0 K or less is anticipated.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ruf, Christopher S., Janssen, Michael A., Keihm, Stephen J.. 1989-01-01. TOPEX microwave radiometer system calibration - Refining the SMMR heritage. https://ntrs.nasa.gov/citations/19910030911