Abstract

An experimental evaluation of Pd 13 percent Cr and of BCL-3 alloy wire strain gages was conducted on IN100 and Cu 0.15 percent Zr alloy substrates. Testing included apparent strain, drift, gage factor, and creep. Maximum test temperature was 1144 K (1600 F). The PdCr gages incorporated Pt temperature compensation elements. The PdCr gages were found to have good resistance stability below 866 K (1100 F). The BCL 3 gages were found to have good resistance stability above 800 K (981 F), but high drift around 700 K (800 F).

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Anderson, W. L., Grant, H. P.. 1992-02-01. High temperature strain gage technology for hypersonic aircraft development applications. https://ntrs.nasa.gov/citations/19920012996