NASA NTRS ยท 19920017863
Results from the LDEF/A0076 cascaded variable conductance heatpipe experiment
Abstract
The A0076 Variable Conductance Heat Pipe Experiment (CVCHPE) on the Long Duration Exposure Facility (LDEF) demonstrated temperature control better than +/- 0.3 C during fifty days on on-orbit data collection in a widely varying external environment. The experiment used two series connected, dry reservoir variable conductance heat pipes which require no electrical power for operation. The heat pipes used a central artery design with ammonia working fluid and nitrogen control gas. The LDEF was in orbit for almost six years rather than the planned one year mission. Although no additional data were taken during this extended period, post-test data indicated that the set point drifted upward less than 1 C per year. There were significant changes to the appearance of all external thermal control surfaces primarily due to atomic oxygen degradation, and one small anomaly in the electronics. These changes, though, had little effect on the CVCHPE performance.
Keep this discovery
Explore connections, maps & timelines
Grote, Michael G.. 1992-01-01. Results from the LDEF/A0076 cascaded variable conductance heatpipe experiment. https://ntrs.nasa.gov/citations/19920017863
Cite the original work for its findings. Save a collection to share your selection of sources.